l' TENNESSEE VALLEY AUTHORITY.
CH ATTANOOGA. TENNESSEE 374ol 1 6 400 Chestnut Street Tower II 4
-C ED e
October 15, 1980 f
Mr. James P. O'Reilly, Director i
4 Office of Inspection and Enforcement 4
U.S. Nuclear Regulatory Commission j
Region II - Suite 3100 101 Marietta Street-l Atlanta,. Georgia 30303
Dear Mr. O'Reilly:
OFFIg.LOF -INSPECTION, AND ENFORCEMENT BULLETIN 80 RII:JPO of259, -260,g BROWS PERRY NUCLEAR PLANT In response to IE Bulletin 80-13 we have performed an inspection of 1
the core spray spargers on Browns Ferry Nuclear Plant unit 2.
Enclosed are the basic procedures and results of that inspection.
1 If you have any questions, please call Jim Domer at FTS 857-2014.
I Very truly yours, TENNESSEE VALLEY AUTHORITY T
, M. Mills, Manager Nuclear Regulation and Safety SubscribedaJn sworn to efo7e me this / f _ day of
(. Cf - 1980.
j 0h 1 5s
~
t Notary Public
)
My Commission Expires 3 1
Enclosure cc: Office of Inspection and Enforcement (Enclosure)
U.S. Nuclear Regulatory Commission Division of Reactor Operations Inspection Washington, DC 20555 1
l i
J 0 /f
' " :g qf t
An Equal Opportunity Employer l
- ~
- - ~
ENCLOSURE IE BULLETIN 80-1 JORE SPRAY SPARGER I!!SPECTIO!!
BR0k"15 FERRY flUCLEAR PLANT UNIT 2 (DOCKET NO. 50-260)
A visual inspection of the core spray spargers on Browns Ferry unit 2 was performed on September 11, 1980.
TVA Mechanical Maintenance Instruction 14.3-A was used for guidelines in performing the inspection.
Resolution of the camera was demonstrated before the inspection by test inspecting a metallurgical sample with 1-mil cracks.
No abaormalities were found.
Exposure to each of the four individuals performing the inspection was 10 millirem.
l
\\.
.-