Ack Receipt of 801017 Final Deficiency Rept Re Documentation Packages for Westinghouse Supplied Matls Missing Quality Records
ML19340B839
Person / Time
Site: Marble Hill
Issue date: 10/29/1980
From: Fiorelli G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Shields S
PSI ENERGY, INC. A/K/A PUBLIC SERVICE CO. OF INDIANA
References
NUDOCS 8011120417
Download: ML19340B839 (1)


Text

kW4 UNITED STATU 9

0,,

NUCLEAR REGULATORY COMMISSION

+

[

o REGION lil E

f 799 ROOSEVELT ROAD f

GLEN ELLYN, ILUNOIS 601M OCT 2g 1999 Docket No. 50-546 Docket No. 50-547 Public Service of Indiana ATTN:

Mr. S. W. Shields Senior Vice President Nuclear Division Post Office Box 190 New Washington, IN 47162 Gentlemen:

Thank you for your final report dated October 17, 1980, pursuant to 10 CFR 50.55(e) regarding documentation packages for Westinghouse sup-plied materials m!.<, sing quality records. We will complete our review of this matter during a future inspection.

Your cooperation with us is appreciated.

Sincerely, f

s Gaston Fiorelli, Chief Reactor Construction and Engineering Support Branch cc: Director, RCI/IE Director, AEOD Chief, OEB/MPA IE Files Mr. G. N. Brown, Proj ect Director C. Kamrrerer, CA cc w/ltr dtd 10/17/80:

Central Files PDR Local PDR NSIC TIC LeBoeuf, Lamb, Leiby & MacRae Mr. Dave Martin, Office of

' Attorney General Mr. John R. Galloway, Staff Director, Environment, Energy and Natural Resources Subcommittee fotli a-o t 7

1017804010

)

y. n 4}- ny

_/

i

..;n d PUBLIC

' SERVICE INDIANA '

i S. W. Shields Senior Vice Presdent -

Nuclear Division October 17, 1980 Mr. James G. Keppler, Director Docket Nos.:

STN 50-546 U. S. Nuclear Regulatory Commission STN 50-547 4

Region III Construction Permit Nos.:

799 Roosevelt Road CPPR - 170 Glen Ellyn, Illinois 60137 CPPR - 171

)

Marble Hill Nuclear Generating Station - Units 1 and 2

Dear Mr. Keppler:

On July 7, 1980, Mr. C. E. Chmielewski of Public Service Company I

of Indiana, Inc., (PSI) notified your office of a potentially reportable I

item as required by 10 CFR 50.55(e). A review of Westinghouse j

quality verification packages performed under SPP-7 had indicated 46 nonconu rmances out of a sample size of 49 document packages.

l Since that time acceptable dispositions have been obtained on all 46 nonconfc rmances previously identified. Examining these dispositions i

the following conclusions can be drawn.

a.

The nonconfc mances generated reflect differences in the Westinghouse and PSI Quality Assurance Programs as opposed to a deficies.cy in either.

b.

Westinghouse is contractually PSI's lifetime retention of Westinghouse NSSS records. Future reviews will be limited to those records which are necessary to verify compliance with the Westinghouse Quality Assurance Program.

c.

The Westinghouse Quality Assurance Records Management Program has provided PSI with the necessary confidence level by retrieving from within their system the supportive documentation and/or an acceptable justification or resolution of noted deficiencies.

bOAh 101@@fo>

OCT -2 3 2 P.O. Box 190, New Washington, Indiana 47162 812. 293.4441 e

e

.-?

rm.

- e e

s- - - -

-,,e-p

t

_f

.7 7 7

_s.s PUBLIC SERVICE INDIANA Letter
James G. Keppler October 17, 1980 Based on PSIs investigation and review of the subject nonconformances and the conclusions presented above, this item is not reportable under 10 CFR 50.55 (e).

If you have any questions on this matter, please feel free to contact me.

S*ncerely, 7'

/

S. W. Shields TDG/cg cc: Director of Inspection and Enforcement U. S. Nuclear Regulatory Commission Washington, D. C.

20555 E. R. Schweibinz, P. E.

J. J. Harrison