ML19340B662
| ML19340B662 | |
| Person / Time | |
|---|---|
| Site: | Peach Bottom |
| Issue date: | 10/24/1980 |
| From: | Office of Nuclear Reactor Regulation |
| To: | |
| Shared Package | |
| ML19340B653 | List: |
| References | |
| IEB-79-01B, IEB-79-1B, IEB-79-1B-S2, NUDOCS 8011110582 | |
| Download: ML19340B662 (2) | |
Text
D T
~
!,?
p
'D f
{
e{ A.
_ tk
=
i v
hJ PBAPS 6.10.2
, Continued d.
Records of radiation exposure for all individuals entering radiation control areas.
e.
Records of gaseous and liquid radioactive material released to the environs.
f.
Records of transient or operational cycles for those facility components designed for a limited number of transients or cycles.
g.
Records of, training and qualification for current members of the plant staff.
h.
Records of in-service inspections performed pursuant to these Technical Specifications.
i.
Records of Quality Assurance activities required by the QA Manual, except as described in 6.10.1 above.
j.
Records of reviews performed for changes made to procedures or equipment or reviews of tests and experiments pursuant to 10 CFR 50.59.
k.
Rei>rds of meetings of the PORC and the OSR Comittee.
1.
Records for Environmental Qualification which are covered under the provisions of paragraph 6.16.
6.11 Radiatior. Fr:tection Procra-Procedures fcr personnel radiation protection shall be prepared consistent with requirements of 10 CFR Part 20 and shall be approved, maintained and adhered to for all operations involving personnel radiation exposure.
6.12 Fire Protectior. Inspections a.
An indepencent fire protectica and loss prevention program inspection shall be performed at least once per 12 months utili:in; either qualifieg offsite licensee personnel or an outside fire protection firm.
b.
An inspe: tion of the fire protection and loss prevention program i
shall be performed by a qualified outside fire consultant at '
least once per 36 months.
8011110 ${
Amendment No. f, Order dtd.
-261-October 24, 1980 t
l 1
PBAPS 6.16 ENVIRONMENTAL QUALIFICATION a.
By no later than June 30, 1982 all safety-related electrical equipment in the facility shall be qualified in accordance with the provisions of Division of Operating Reactors " Guidelines for Evaluating Environmental Qualification of Class IE Electrical Equipment in Operating Reactors"(DOR Guidelines) or, NUREG-0588 " Interim Staff Position on Environnental Qualification of Safety-Related Electrical Equipment",
December 1979. Copies of these documents are attached to Order for Modi-fication of License DPR-56 dated October 24, 1980.
b.
By no later than December 1,1980, complete and auditible records must be available and maintained at a central location which describe the 6
environmental qualification method used for all safety-related electrical equipment in sufficient detail to document the degree of compliance with the DOR Guidelines or NUREG-0588. Thereafter, such records should be updated and maintained current as equipment is replaced, further tested,-
or otherwise further qualified.
Order dated October 24, 1980
-264-m L
,