O ADMINISTRATIVE CONTROLS 6.10 RECORD RETENTION In addition to the applicable record retention requirements of Title 10, Code of Federal Regulations, the following records shall be retained for at least the minimum period indicated.
6.10.1 The following records shall be retained for at least five years:
a.
Records and logs of unit operation covering time interval at I
each power level.
b.
Records and logs of principal maintenance activities, inspections, repair and replacement of principal items of equipment related to nuclear safety.
c.
ALL REPORTABLE OCCURRENCES submitted to the Comission, d.
Records of surveillance activities, inspections and calibrations required by these Technical Specifications.
e.
Records of c.hanges made to the procedures required by Specifica-tion 6.8.1.
f.
Records of radioactive shipments.
g.
Records of sealed source and fission detector leak tests I
and results.
h.
Records of annual physical inventory of all sealed source material of record.
M6.10.2 The following records shall be retained for the duration'of the i:cility Operating License:
t l l a.
Records and drawing changes reflecting unit design modifications 0
made to systems and equipment descr'ibed in the Final Safety Analysis Report.
l b.
Records of new and idradiated fu'el inventory, fuel transfers i
and assembly burnup histories.
l i
c.
Records of radiation exposure for all individuals entering r
radiation control areas.
f d.
Records of gaseous and liquid radioactive material released to the environs.
e.
Records of transient of operational cycles for.those unit.com-D ponents identified in Table 5.7-1.
' ARKANSAS - UNIT 2 6-19 8011110347
[
?
N, ADMINISTRATIVE CONTROLS r
f.
Records of reactor tests and experiments.
Records of training and qualification for current members of g.
i the unit staff.
I Records of in-service inspections performed pursuant to these h.
Technical Specifications.
1.
Records of Quality Assurance activities required by the QA Manual.
J.
kecords of revi,ews performed for changes made to procedures or equipment or reviews of tests and experiments pursuant to 10 CFR 50.59..
k.
Records of meetings of the PCS and the SCR.
j Records of changes to the Corc Protection Calculetor Systen l
1.
(CPCS) SOFTWARE. Changes to the CPCS SONWARE shall be made in j
i accordance with. methods approved by the NRC. These records shall include the following:
l l
l 1.
Purpose of change.
?
I 2.
Detailed description of change including algorithms, 4
I changes to the assembly listings, checksums and disk identification numbers..
l 3.
Summary of validation test results.
j.
i g
m.
Records of Environmental Qualification which are covered under the provisions of paragraph 6.12.
i j 6.11 RADIATION PROTECTION PROGRAM 1'
! Procedures.for personnel. radiation protection shall be prepared consistent e
- with the requirements of 10 CFR Part 20.and shall be approved, maintained and adhered to for all operations involving personnel radiation exposure.
l l6.12 ENVfRONMENTAL QUALIFICATI04 i
16.12.1. By no later than June.30,1982 ll' safety-related electrical equipment t
iin the-facility shall be: qualified in accordance with the provisions of i
! Division.of. Operating Reactors " Guidelines for Evaluating Environmental
! ualification of Class IE Electrical Equipment in Operating Reactors" (DDR k
Q
. Guidelines); or:NUREG-0588 " Interim Staff Position on Environmental Qualific.a-tion. oft Safety-Related Electrical Equipment", Dei: ember 1979.
Copies of these j
documents are. attached to: Order for: Modification of License NPF-6 dated I
October 24, 1980.
ARKANSAS:- UNITJ2:
6-20.
Order dated October 24,1980
ADMINISTRATIVE CONTROLS 6.12.2 By no later than December 1,1980, co;.'lete and auditable records must be available and maintained at a central location which describe the environmental qualification method used for all safety-related electrical equipment in sufficient detail to document the degree of compliance with the D0R Guidelines or NUREG-0588.
Thereafter, such records should be updated and maintained current as equipment is replaced, further tested.
or otherwise further qualified.
I ARKANSAS - UNIT 2 6-21 Order dated October 24, 1980
.