Forwards Review of BAW-10047,Revision 1, & Provides Schedule for Results of Testing & Surveillance Programs
ML19340A417
Person / Time
Site: Crystal River 
Issue date: 10/11/1972
From: Deyoung R
US ATOMIC ENERGY COMMISSION (AEC)
To: Mallay J
BABCOCK & WILCOX CO.
Shared Package
ML19340A418 List:
References
NUDOCS 8003260735
Download: ML19340A417 (1)


Text

.

pu c,

e UNITED STATES

/

g*t; ATOMIC ENERGY COMMISSION J - g;- g ",

WASHINGTON. O.C.

20545 m,;,./j OCT11372 Mr. James F. Mallay Manager, Licensing Babcock & Wilcox P. O. Box 1260 Lynehburg, Virginia 24505

Dear Mr. Hallay:

~.

The regulatory staff has completed its review of Babcock & Wilcox Topical Report BAW-10047, Revision 1, dated August 1972 and entitled "A Study of Discontinuities in Control Rod Drive Motor Tube Extensions."

You have indicated that this revision replaces the original Topical Report BAU-10047, June 1972. A summary of our review is enclosed f or your information.

As a result of our review, we have concluded that Topical Report BAW-10047,; Revision l' will be acceptable by reference in applications for construction permits and ' operating licenses provided the results of the testing and surveillance programs are consistent with the information supplied in this report. We understand that Oconee Nuclear Station Unit

'2 has been selected for these programs. The results of the testing program should be reported to us within sixty (60) days upon completion of the tests 'and the results of-the surveillance program should be l

reported within sixty (60) days upon the end of the first of the fuel cycles. The Topical Report should be revised or supplemented to include the results of these programs.

t Sincerely,

'*f C

R. C. DeYoung, Assistant Director

-for Pressurized Water Reactors Directorate of Licensing

Enclosure:

Topical Report Evaluation s

., Os

  • =+%,

8003260 N i

.