I a

l l

O Form N AC418 U.S. NUCLEAR AEGULATCRY CoMMIS$1oN n2 733 CERTIFICATE OF COMPLIANCE

,n gpq 7, For Aadioactive Materials Packages 1.lai Certificate Numoer 1.!b) Aewisaan No.

1.lci Package identsfication No.

1.idl Pages No. 1.le) Total No. Pages 6089 2

USA /6089/AF 1

2

2. P A E AM S LE 2.tal This certificate is issued to satisfy Sectens 173.393a.173.394. IT3.395. and 173.396 of the Geoertment of Transoortation Nazarcous Maioriais Aegusations 149 CF A 170189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the escartment of Transportat.on oangerous Cargoes Aegulations (46 CF A 146-1491, as amendas.

2.Ibi The oscuaging and contents described in item 5 beeow. meets the safety standaros set forth in Succart c of Title 10. Code of Federal Aegulations. Part 71. ~~ Packaging of Radeoective Materiais for Transoort and Transoortation of Racioactrwe Matenal Under Certain Condations.

2.fc)

This corteficate does not reheve the consegnor from como8ience meth any requirement of the regulations of the U.s. osoortment of Transportation or other sopsicaole regulatory. agencies. inducing the government of any country through or into whsch the package will De transoorted.

3. Thes certificate r:t issued on the basis of a safety anaeysis report of the package desegn or aposicatson-3.lal Precered by (Name and address):

3.fb)

Title and centsfication of report or apoJication:

General Atomic Company Gulf General Atomic, Inc., application P. O. Box 81608 dated October 21, 1968, as supplemented.

San Diego, CA 92136 3.(c) oocket No.71-6089 4 CoNOITICNS This certificate is concitional upon the fulfill ng of the reouirements of Sucoart D of 10 CFR 71, as soo6scanee, and the conditions sosofief in item 5 be6ow.

5. Gescriotion of Pacmaging and Autnonged Contents. Model Nurncer. Fissile Cless. other Conditions. and Aeferences:

(a) Packaging (1) Model No.:

33-FE-100 (2) Description A rectangular box, constructed of minimum 1/4" thick steel, approximately 20-1/2" x 20-1/2" x 147" long with flanged, bolted closure.

Internal surfaces of the steel box, excluding the ends, shall be cadmium plated to a minimum 0.0025" thickness.

Fuel element cavities are formed by 4" OD 18 gage steel tubes lined with cardboard.

Container is encased in 4" thick plywood box which is, in turn, encased in a steel shipping cage.

Total weight, including contents, is 2,500 pounds.

(3) Drawings The packaging is constructed in accordance with Gulf General Atomic l

Drawings Nos. 33-FE-100; FFE-601, Sheet 3, Issue B; and FFE-601, Sheet 4, Issue C.

l 8102]70/b l

1

(

Page 2 - Certificate No. 6089 - Revision No. 2 - Docket No. 71-6089

5. (b)

Contents (1) Type and form of material Peach Bottom fuel elements containing not more than 291 grams U-235 with an overall moderating ratio of carbon te U-235 of 2400 to 1.0.

Each fuel element is approximately 4" in diameter by 144" lone; containing pyrolytic-coated U-Th dicarbide blended with graphite and rhodium metal compacts loaded around a graphite sleeve. Graphite end reflectors are attached to each end of the loaded sleeve.

(2) Maximum quantity of material per package Twenty-five (25) Peach Bottom fuel elements containing not more than 7.2 Kg U-235 and not more than type A quantity radioactive material.

(c) Fissile Class II and III (1) Minimum transport index to be shown on label for Class II 0.4 per fuel element (2) Maximum number of packages per shipment for Class III Six (6) 6.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).

7.

Expiration date:

December 31, 1981.

REFERENCES Gulf General Atomic, Inc. application dated October 21, 1968.

Supplements dated:

October 29, November 25, and December 24, 1969; January 21 and July 6, 1970.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION 1

-u Charles acDonald, Chief Transportation Certification Branch Division of Fuel Cycle and t

Material Safety I

Date:

JAN 2 61991 l

l I

<