Forwards LER 81-002/03L-0
Date released: 12/19/2019 Download: ML19339C866


LER 81-002/03L-0:on 810113,post Acceptance Review of Annual Test Results from 04-80,for Control Room Emergency Filtration Sys,Showed 1980 Annual Test Incomplete.Caused by Personnel Failing to Determine Sys Velocity & Flow Info
ML19339C867
Person / Time
Site: Point Beach NextEra Energy icon.png
Issue date: 02/04/1981
From: Fay C
WISCONSIN ELECTRIC POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19339C867 (2)
Forwards LER 81-002/03L-0
ML19339C865
Person / Time
Site: Point Beach NextEra Energy icon.png
Issue date: 02/04/1981
From: Fay C
WISCONSIN ELECTRIC POWER CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19339C865 (1)