05000331/LER-1981-002, Forwards LER 81-002/03L-0

From kanterella
(Redirected from ML19339C836)
Jump to navigation Jump to search
Forwards LER 81-002/03L-0
ML19339C836
Person / Time
Site: Duane Arnold NextEra Energy icon.png
Issue date: 02/05/1981
From: Mineck D
IES UTILITIES INC., (FORMERLY IOWA ELECTRIC LIGHT
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML112410872 List:
References
DAEC-81-80, NUDOCS 8102120062
Download: ML19339C836 (1)


LER-1981-002, Forwards LER 81-002/03L-0
Event date:
Report date:
3311981002R00 - NRC Website

text

'

~.

1 1

N Iowa Electric 1.ight anti Power Company February 5, 1981 h

g I.

L(J DAEC-81-80

@;W"FEB10;9 m,w-Mr. James G.

Keppler, Director office of Inspection and Enforcement y

9' U.

S. Nuclear Regulatory Commission - Region III cna t.P 799 Roosevelt Road Glen Ellyn, IL 60137

Subject:

Licensco Event Report No.81-002 (30 day)

File:

A-ll8a

Dear Mr. Koppler:

In accordance with Appendix A to Operating License DPR-49, Technical Specifications and Bases for Duane Arnold Energy Center and Regulatory Guide 10.1, please find attached a copy of the subject Licensec Event Report.

(Total of 3 copies transmitted).

Very truly yours, 1%./

gg Daniel L.

Mineck i

Chief Engineer Duane Arnold Energy Center Docket 50-331 i

f attachment s

DLM/M,SR/pl cc:

Director, Office of Inspection and Enforcement (30)

U.

S. Nuclear Regulatory Commission Washington, D.

C.

205S5 Director, Management Information and Program Control (3)

U.

S.

Nuclear Regulatory Commission Washington, D.

C.

20555 P

Nuclear Regulatory Commission'g SN N D b

U. S.

c/o Document Management Branch MJ Washington, D.

C.

20555 81 0 212 0 cc1litC Itcsident Inspector - DAEC I

g Ikr.orn AssusM Du une c'erster

  • I*n. I% ;tst
  • O ul.ur It.spink. hnus se tts
  • 3sts/nst-5 Css