Discusses Re Feedwater Hammer Test Procedure. Procedure Should Be Revised to Provide Info Re Test Prerequisites,Precautions,Special Test Equipment & Instrumentation & Data Logs.Requests Resubmission
ML19339C780
Person / Time
Site: Salem 
Issue date: 11/07/1980
From: Tedesco R
Office of Nuclear Reactor Regulation
To: Mittl R
Public Service Enterprise Group
References
NUDOCS 8011190448
Download: ML19339C780 (2)


Text

'

NOV 7 1980 g.

o

~

Docket No. 50-311

.. =, _

Mr. R. L. Mitt 1, General Manager

&lg Licensing and Enviror~ent

~9 y

Q..

Public Service Electric & Gas Canpany 80 Park Plaza - T17A

g,'

ui e

Newark, New Jersey

Dear Mr. Mitti:

SUBJECT:

FEEDWATER HAMMER TEST PROCEDURE We have reviewed your test procedure, "SUP 80.1, Appendix G. Feedwater Hamer Test" submitted as an attachment to your letter dated July 7,1980. Our coments are as follows:

1). The procedure should be revised to provide infomation regarding test prerequisites, precautions, special test equipment and instrumentation, step-by-step test instructions, and data logs;
2) The test should be conducted with a feedwater flow rate which covers the flow rate expected assuming operation of all three auxiliary feedwater pumps (nominally at least 440 gpn per steam generator);
3) Critical pipe hangers should be located in three dimensions with respect to fixed reference points. After the test, they should be remeasured to see if any change has occurred;
4) Pressure transmitters used in the test should have a time co'stant less n

than the expected time constaat of the shock wave; and

5) Strip chart and other records of test pressure and temperature should be saved.

After the test procedure has been revised in accordance with the above coments, it should be resubmitted for NRC review and approval. Should you have any questions on this matter, do not hesitate to contact us.

gg signed by p L, Tedesco Robert L. Tedesco, Assistant Director for Licensing Division of Licensing DISTRIBUTION:

R. 'Tedesco FMiraglia OParr Docket File JKerrigan BMann LB3 Files SMacKay

/1 8 ~011 ] 9 0 POR LPOR OBeckham,

ig(

D7 omer)... LB3 C L.:.NRR...L f NRR..

.ADh,HRR..

.. /...

11/.i.k.....

SURNAMEk.

...h./.80 11 11 80

/.80

,,,, )

RO3 FQQCS 380 69 700 N3sM 084@

DU.S. GOVERNMENT PRINTING OFFICE: 1979 289 369

. k.

tt0V 7 1980

m S

'8 Docket No. 50-311

[

ic) nk~

5 g

+liw

jh Mr. R. L. Mitti, General Manager E

Licensing and Environment m

1 Public Service Electric & Gas Company J

e 80 Park Plaza - T17A FJ; y

Lg Newark, New Jersey

Dear Mr. Mitti:

SUBJECT:

FEEDWATER HAMMER TEST PROCEDURE We have reviewed your test procedure, "SUP 80.1, Appendix G. Feedwater Hammer Test" submitted as an attachment to your letter dated July 7,1980. Our comments are as follows:

1) The procedure should be revised to provide information regarding test prerequisites, precautions, special test equipment and ins'.rumentation, step-by-step test instructions, and data logs;
2) The test should be conducted with a feedwater flow rate which covers the flow rate expected assuming operation of all three auxiliary feedwater pumps (nominally at least 440 gpm per steam generator);
3) Critical pipe hangers should be located in three dimensions with respect to fixed reference points. After the test, they should be remeasured to see if any change has occurred;
4) Pressure transmitters used in the test should have a time co'nstant less than the expected time constant of the shock wave; and
5) Strip chart and other records of test pressure and temperature should be saved.

After the test procedure has been revised in accordance with the above comments, it should be resubmitted for NRC review and approval. Should you have any questions on this matter, do not hesitate to contact us.

p.a1 syned by pet L, TedescQ Robert L. Tedesco, Assistant Director for Licensing Division of Licensing DISTRIBUTION: