[e r eg*o, UNITED STATES M
89 7
NUCLEAR REGULATORY COMMISSION
,Et REGION I 9,
g 631 PARK AVENUE
,e KING OF PRUSSIA, PENNSYLVANIA 19406 DrckeYtios'.50-289 September 30, 1980 Metropolitan Edison Company ATTN:
Mr. R. C. Arnold Senior Vice President 100 Interpace Parkway Parsippany, New Jersey 07054 Gentlemen:
The enclosed Supplement No. 2 to IE Bulletin No. 79-018, " Environmental Qualification of Class 1E Equipment," is enclosed.
This information is presented in the form of generic questions and answers which will assist you in responding to the actions required in IES79-018 and the Memorandum and Order (CLI-80-21) dated May 23, 1980 with regard to environmental qualification of Class 1E equipment in use at your facility.
If you desire additional information regarding this matter, please contact this office.
Sincerely, 4
a o
e H. Grier Director
Enclosures:
1.
Supplement No. 2 to IE Bulletin No. 79-018 2.
List of Recently Issued IE Bulletins CONTACT:
S. D. Ebneter (215-337-5283) cc w/encis:
J. G. Herbein, Vice President-Nuclear Operations E. G. Wallace, Licensing Manager R. J. Toole, Manager, Unit 1 W. E. Potts, Manager, Radiological Controls, Unit 1 J. J. Colitz, Manager, Plant Engineering, Unit 1 R. F. Wilson, Director - Technical Functions L. W. Harding, Supervisor of Licensing I. R. Finfrock, Jr.
R. W. Conrad J. 8. Lieberman, Esquire G. F. Trowbridge, Esquire Ms. Mary V. Southard, Chairperson, Citizens for a Safe Environment 801107 c055 q
SSINS: 6820 Accession No.: ice 12.oM/
UNITED STATES.
NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.
20555 September 30, 1980 IE Supplement No. 2 to Bulletin 79-018: ENVIRONMENTAL QUALIFICATION OF CLASS 1E EQUIPMENT Enclosed are the generic questions and answers which resulted from NRC/ Licensee meetings in NRC Regional Offices during the week of July 14, 1980 regarding environmental qualification of Class IE equipment in use at power reactor facilities.
These answers address specific questions asked during the meetings.
Due to the generic nature of some of these questions, the staff is issuing them as a bulletin supplement.
The regional meetings highlighted the fact that in some cases, the scope and depth of the 79-018 review was not clear to licensees.
Therefore, these answers may affect your 79-018 submittal.
These submittals are required by a separate order to be completed by November 1, 1980.
Some answers given in Supplement No. 1 to IEB-79-018 are superseded by these answers.
For example, in Bulletin Supplement No. 1, issued on February 29, 1980, the answer to question No. 5 specified that TMI lessons learned equipment was not included in the review.
However, due to the extension of the response date from April 14,1980 to No-4er 1, 1980, this equipment is now being addressed since its installat' is either complete or required before the issuance of the February 1, L31 SER.
(See Question No. 21 of this Supplement.)
No specific response is requested by this Supplement; however, all answers contained in the enclosure to this Supplement should be carefully reviewed and considered for applicability in your response to IEB 79-018.
IE Bulletin No. 79-018 was issued under a blanket GA0 clearance (B180225 (R0072); clear.ance expired July 31, 1980) specifically for identified generic problems.
Supplement No. 2 to Bulletin 79-018 is for information, hence no GA0 clearance is required.
l Attachnent:
1.
Generic Questions and Answers to IEB-79-018 and Memorandum and Order (CLI-80-21) dated May 23, 1980 DUPLICATE DOCUMENT Entire document previously entered into system under:
(#6F2 2 d P-W ANO No. of pages: