DOCKET NO. 50-29 HAZARDS ANALYSIS BY TifE RESi" AND POWER REACTOR SAFE.

  • BRANCH DIVISION OF LIC5;NSING AND REC'_.*Ta.:

IN THE MATTER OF YJ.dKEE ATOMIC ELECTRIC COMPANY 2ROPOSED CIIANGE NO 7 Pursuant to the provisions of paragraph 3. A. of License No. DPR-3, as amended, Yankee Atomic Electric Company in Proposed Change No.

7. dated May 8, 1961, requested authorization to install the control circuitry necessary to initiate a trip of the boiler feed pumps in the event of a scram when the reactor is operating at a power level

_.7 above 15 MW electric.

A loss of load accompanied by an immediate reactor scram results in a reduction in the temperature of the primary system. The effect of this temperature reduction is to decrease the shutdown margin, which is particularly significant at the beginning of core life when this margin is at a minimum. The immediate shutdown of the boiler feed pumps as the reactor scrcms results in a smaller temperature reduction p

of the primary system, thereby preserving an adequate shutdown margin i

even at the beginning of core life.

Based on our review of the Proposed Change, we have concluded that it should contribute to safer operation of the facility and that it does not present significant hazards considerations not described or Iwplicit in the license application. We have further concluded that there is reasonable assurance *'.: the health and safety of the public will not be endangered by operacion of the facility as proposed.

Edson G. Case, Chief Research and Power Reactor Safety Branch Division of Licensing and Regulation Date: MAY 2 5 iSCl 8011060 Q g

--