Text
h#
'o UNITED STATES l'
NJCLEAR REGULATORY COMMISSION w
... j REGION I 3,
g 631 PARK AVENUE g,
KING oF PRUSSIA, PENNSY1.VANIA 19406 October 24, 1980 o
[I U
Docket No. 50-322 i;
,j Long Island Lighting Company
$7
..s ATTN:
Mr. M. S. Pollock kd ;
Vice Presifent - Nuclear 2R' 175 East Old Country Road
[j 2
Hicksville, New York 11801 f,'
u, m
u
',3 Gentlemen:
The enclosed IE Information Notica No. 80-37, "Contain:nent Cooler Leaks and Reactor Cavity F1 coding at Indian Point Unit 2,"
is for warded to you for information.
No written response is required.
If you desire additional information regarding this matter, please contact this office.
Sincarely, r
ce H. Grier Director
Enclosures:
1.
IE Information Notice No. 80-37 2.
List of Recently Issued IC Information Notices CCNTACT:
E. G. Greenman (215-337-5257) cc w/encis:
J. P. Novarro, Project Manager Edward M. Barrett, Esquire Edward J. Walsh, Esquire T. F. Gerecke, Manager, Engineering QA Deoart:nent 8011060
(.3 6
D
- D e9 29 es 22 SSINS No.:
6835 Accession No.:
8008220249 UNITED STATES IN 80-37 NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.
20555
~~~~
October 24, 1980 IE Information Notice No. 80-37:
CONTAINMENT COOLER LEAKS AND REACTOR CAVITY FLOODING AT INDIAN POINT UNIT 2 Discriotion of Circumstances:
This Notice contains information regarding multiple service water leaks into containment with resulting damage to reactor instrumentation and potential damage to the reactor pressure vessel.
Upon containment entry on October 17, 1980 at Indian Point Unit 2, to repair a malfunctioning power range nuclear detector, it was discovered that a significant amount of water was collected (approximately 100,000 gal) on the containment floor, in the containment sumps, and in the cavity under the reactor pressure vessel (RPV). This collected water probably caused the detector malfunction, and the water in the cavity under the RPV is believed to have been deep enough
- to ;et several feet of the pressure vessel lower head, causing an unanalyzed thermal stress condition of potential safety significance.
This condition resu'lted from the following combination of conditions:
(1) Both containment sump pumps were inoperable, one due to blown fuses from an unknown cause and the other due to binding of its controlling float; (2) The two containment sump level indicating lights which would indicate increasing water level over the water levr1 range present in the containment were stuck (on) and may have been for several days, leaving the operator with no operable instrumentation to measure water level in the containment; (3) The moisture level indicators in the containment did not indicate high moisture levels, apparently because they are designed +o detect pressurized hot water or steam leaks (i.e., a LOCA), and are not sensitive to the icwer airborne moisture levels resulting from relatively small cold water leaks; (4) The hold-up tanks which ultimately receive water pumped from the containment sump also receive Unit 1 process water, lab drain water, etc.
These other water sources masked the effect of cessation of water flows from the Unit 2 sump; (5) There were significant, multiple service water leaks from the containment fan cooling units directly onto the containment floor.
These coolers have a history of such leakage, which cannot be detected by supply inventory losses since the supply system (service water system) is not a closed system; (6) The two submersible pumps in the cavity under the Reactor Pressure Vessel were ineffective since they pump onto the con-tainment floor for ultimate removal by the (inoperable) containment sum pumps.
There is no water level instrumentation in the cavity under the RPV, noi-was there any indication outside the containment when these pumps are running.
The licensae has installed redundant sump level annunciated alarms in the control room and has installed an annunciated alarm in the control room to indicate if either submersible pump in the reactor cavity activates.
The licensee has also repaired the service water leaks, installed guide bushings on the sump pump control floats to prevent their binding, ar.d has repaired the containPent sump water level indicators.
w m
m r
r
---r
~
IN 80-37 l
October 24, 1980 Page 2 of 2 The licensee plans in the longer term to replace the containment fan unit cooling cofis.
It is anticipated that results of a continuing NRC investigation into this incident will result in issuance of an IE Bulletin and/or an NRR Generic Letter in the near future which will reccamend or require specific licensee and appifcant actions.
In the interiu, we recommend that all licensees ascertain that the potential does not exist for undetected water accumulation in the containment.
This Information Notice is provided to inform ifcensees of a possibly significant satter.
No written response to this Information Notice is required.
IE Information Notice No. 80-37 October 24, 1980 RECENTLY ISSUED IE INFORMATION NOTICES Information Subject Date Issued to Notice No.
Issued 80-36 Failure of Steam 10/10/80 All holders of a Generator Support power reactor Bolting OL or CP 80-35 Leaking and Dislodged 10/10/80 All holders of a Iodine-12S Implant Category G or G1 Seeds Medical License 80-34 Boron Dilution of 9/26/80 All holders of a Reactor Coolant During PWR Power Reactor OL Steam Generator Decontamination 80-33 Determination of 9/1S/80 All holders of Telotherapy Timer a teletherapy Accuracy license 80-32
rification of 9/12/80
'1' holders of
- af n Requirements
- or Agreement
.-or Exclusive-use sca s License Shipments of Radioactive Materials 80-31 Maloperation of Gould-8/27/80 All holders of Brown Boveri 480V-Type a power reactor K-6005 and K-Don 6005 OL or CP Circuit Breakers 80-30 Potential for Unaccept-8/27/80 All holders of able Interaction a BWR power reactor Between the Control OL or CP Rod Drive Scram Function and Non-essential Control Air at Certain BWR Facilities 80-29 Broken Studs on 8/7/80 All holders of Terry Turbine a power reactor Steam Inlet Flange OL or CP Supplement Notification of 7/29/80 All holders of a to 80-06 Significant Events power reactor OL at Operating Power and near term OL Reactor Facilities applicants