T o

Florida Power o,,,,. n...

Detober 2 4, 1980 Director Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Conmission Washington, D. C.

20555 Subj ect: Crystal River-Unit 3 Docket No. 50-302 Operating License No. DPR-72 Containment Leakage Rate Tests

Dear Sir:

Please find attached fifteen (15) copies of the report detailing the results of testing conducted at 0 ystal River Unit 3 during the last refueling outage in accordance with 10 CFR 50, Appendix J.

'Ihe report provides the results of Type A, B, and C tests and is sutmitted within three months of completion as required by Section V.B.3 of the aforementioned Appendix. 'lhe results of the test danonstrated the continued functional capability of the reactor containment building with regard to leakage at accident pressures.

Very truly yours, FLORIDA POWER CORPORATION

{,

Ronald M. Bright Acting Manager Nuclear Support Services DPR-72cs H3'i e-FILE:

3-0-9 snf.1:3 W, bO II 'O 9 AC;; pq u>

3 U" 1 00)0 General Office 3201 In.nyaounn sneet soutn. P o Bo t4042. st Peimburg. noruu 33a3. si3 - ees sisi L

r-l l

l STATE G' FLORIDA COUNTY OF PINELLAS R. M. Bright states that he is the Acting Manager, Nuclear Support Services, of Florida Power Corporation; that he is authorized on the part of said cmpany to sign and file with the Nuclear Regulatory Commission the inforrration attached hereto; and that all such statmens made and matters set forth therein are true and correct to the best of his knowledge, information and belief.

/14 H./M. Eright Subscribed and sworn to before me, a Notary Public in and for the State and County above nmed, this 24th day of October,1983.

t Notary Public Notary Public, State of Florida at Large, My Comission Expires:

August 24,1983 l

.