i
('>)
~
ENCLOSURE DESC"IPTIO:' 0F VIOLATIC'.:S Yanhec Atenic Electric Company 20 Turnpike Road b'estboro, :Mssachusetts 01581 Certain activities under your license appear to be in violation of AEC requirements. These apparent violations are considered to be of Category II severity.
1.
Technical Specifications, Paragraph D.1 states, in part,
"...All plant operations...shall be conducted in accordance with written procedures Yankee Operating Procedure, Primary Systen "ater Balance, OP-4220, a.
states, in part,
---Step by step instructions are provided on the forms to determine the primary plant accountable and vCoccountable leak rate..."
Contrary to the above the calculations performed on !! arch 2 and 3, 1974, "a o not acco:plished in accordance uith the procedures.
b.
Yankee Operating Procedure, OP8100, Establishing and Posting Con-trolled Areas, states, in part,
---All contrclied areas shall be adequately surveyed to insure that the boundaries established con-pletely define the controlled area--."
Contrary to the above, on >brch 1.2, 1974, the boundary established did not completely define the contaminated area identified in the New Fuel Storage Vault.
e G
.h 801105023 0