._

i UNITED STATES

/f "%g$

NUCLEAR REGULATORY COMMISSION c'

naciom iv f

, TEN No 2

k 2 7 JUN 1980 (J,..... /

Docket No. 99900255/80-01 Pacific Scientific Kin-Teck Division Attn: Mr. P. A. Hadnagy Quality Assurance Manager 1346 S. State College Boulevard Anaheim, CA 92803 Gentlemen:

Thank you for your letter of May 28, 1980, in response to our letter dated March 5,1980. As a result of our review, we find that addi'tiunal information, as discussed with you during a telephone call on June 23, 1980, is needed, as follows:

l.

Relative to Deviation A, what actions have been or will be taken to prevent a recurrence of this or a similar deviation and the date of when corrective action will be completed.

2.

Relative to Deviation B, please address your corrective action, relative to the shop order number noted in the deviation and the date of when the corrective actions to prevent recurrence will be completed.

3.

Relative to Deviation C, please spectfy how instructions to the involved personnel were documented and what actions were taken to assure that the corrective actions are effective.

Please provide this additional information within twenty (2Q}. days in order that we may complete our review in a timely manner, Sincerely, c/

Uldis Potapovs, Chief Vendor Inspection Branch 8011040/25-