ML19339A291

From kanterella
Jump to navigation Jump to search
Forwards LER 80-160/03L-0
Date released: 12/19/2019 Download: ML19339A291


LER 80-160/03L-0:on 800926,containment Differential Pressure Re Annulus Exceeded Tech Spec Limits During RCS Heatup. Caused by Containment Atmosphere Heatup & Normal Control Air Leakage.Pressure Reduced by Venting
ML19339A293
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 10/24/1980
From: Cottle W, Kirk G
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19339A293 (2)
Forwards LER 80-160/03L-0
ML19339A290
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 10/24/1980
From: Calhoun J
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19339A290 (1)