The Light Company Hou5 ton Lighting & Power PO. Box 1700 Houston, Texas 77001 (713)228-9211 October 16, 1980 ST-HL-AE-559 SFN: V-0530 Mr. Karl Seyfrit Director, Region IV Nuclear Regulatory Comission 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76012

Dear Mr. Seyfrit:

South Texas Project Units 1&2 Docket Nos. STN 50-498, STN 50-499 Second Interim Report Concerning the Essential Cooling Water Pump Seal Water Design Deficiency On July 3,1980, pursuant to 10CFR50.55(e), Houston Lighting & Power Company notified your office of a deficiency concerning the design of the seal water injection system for the Essential Cooling Water (ECW) pumps.

An interim report on this matter was submitted to your office on August 1, 1980. This letter provides infonnation on the present status of this subject deficiency.

As provided in our first repo'rt, dated August 1,1980, alternate design solutions are currently being evaluated. A preliminary design has been developed, however a detailed review and final approval remains to be perfonned.

12,1980.garding this deficiency will be submitted to your office by The next recort re December If there are any questions, please contact Mr. M. E. Powell at (713) 676-8592.

Very truly yours,

. /--

/

rea Exe ive President g

TAP /pjb S

I/

8 0103.10 2$

Houuon Lighting & Power Compan)

October 16, 1980 ST-HL-AE-559 SFN: V-0530 Page 2 cc:

D. G. Barker Howard Pyle R. L. Waldrop H. R. Dean D. R. Beeth J. D. Parsons G. B. Painter L. K. English A. J. Granger R. A. Fra:ar H. S. Phillips (NRC)

J. O. Read (Read-Poland,Inc.)

M. D. Schwarz (Baker & Botts)

R. Gordon Gooch (Baker &Botts)

J. R. Newman (Lowenstein, Newman, Reis, Axelrad & Toll)

Director, Office of Inspection & Enforcement Nuclear Regulatory Commission Washinqton, D.C.

20555 I

I i

l

-- - ~

Houston Lighting & Power Company October 16, 1980 ST-HL-AE-559 SFN: V-0530 Page 3 M. L. Borchelt Executive Vice President Central Power 6 Light Company P. O. Box 2121 Corpus Christi, Texas 78403 R. L. Range Central Power S Light Company P. O. Box 2121 Corpus Christi, Texas 78403 R. L. ilancock i

Director of Electrical Utilities City of Austin P. O. Box 10SS Austin, Texas 78767 T. H. Muehlenbe:k City of Austin P. O. Box 1088 4

Austin, Texas 78767 J. B. Poston Assistant General Manager of Operations i

City Public Service Board P. O. Box 1771 San Antonio, Texas 78296 A. vonRosenberg City Public Service Board P. O. Box 1771 San Antonio, Texas 78296 A

\\

Houston Ughting & Power Company October 16, 1980 l

ST-HL-AE-559 SFN: V-0530 Charles Bechoefer, Esquire Page 4 Chairman, Atomic Safety 6 Licensing Board U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Dr. James C. Lamb, III 313 Woodhaven Road Chapel Hill, North Carolina 27514 Dr. Emmeth A. Luebke Atomic Safety 6 Licensing Commission U. S. Nuclear Regulatory Commission Washington, D. C.

20555 Steven A. Sinkin, Esquire 116 Villita Street San Antonio, Texas 78205 Citi: ens for Equitable Utilities e/o Nb. Peggy Buchorn Route 1, Box 432 Bra:oria, Texas 77422 Richard W. Lowerre, Esquire Assistant Attorney General for the State of Texas P. O. Box 12548 Capitol Station Austin, Texas 78711 Bernard M. Bordenick Hearing Attorney Office of the Executive Legal Director U. S. Nuclear Regulatory Commission Washington, D. C. 20555 o&=*e