.ND" d I 3pp g

" h*

U j'

' J

~ j 6

3RU:iSWICK U:ili 2 N0ZZLE INSPECTIO:: PROGRAM SAFETY E'/ALUATICN RE?CRT ENGINEERING 3 RANCH DIVISION OF CPERAT!NG REA" TORS 1.0 !NTRCDUCTION Sy letter datcd June la,1979, Carolina P:wer and Light Corrpany presented the results Of tne 1979 inspecticas Of t e #ee:nter anc COC return line 102:les.

This inspection was per#3med to Oa:is fy the requirements :# Nuo.EG - 2312.

2.0 EVALUATION The enclosed Technical Evalua*, ion Repor nas prepared f;r as by our Contract:c, Franklin Researcn Cen;er, as cart of tne NRC Ccn rac: No. NRC-03-79-li3.

2.0 CONCLUSION

S 3ased on our review o' the enciased C:ntrac:0r's Tecnnical Evaluation Re:c-,

we agree witq their fincings tha t.e Licensees 1:79 ins;ection arcgran sas acceptacle.

The final resolation of tne 3WR no :le crac<ing proolem wil! ' e:

addressec in NURE3-0619.

t 8010310