ML19338G349

From kanterella
Jump to navigation Jump to search
Notice of Deviation from Insp on 800909-12
ML19338G349
Person / Time
Issue date: 09/24/1980
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To:
Shared Package
ML19338G340 List:
References
REF-QA-99900268 NUDOCS 8010290122
Download: ML19338G349 (1)


Text

.

~

( )

Armco Incorporated Advanced Material Division Docket No. 99900268/80-02 NOTICE OF DEVIATION Based on the results of an NRC inspection conducted on September 9-12, 1980, it appears that one of your activities was not conducted in accordance with NRC requirements.

Criterion V of Appendix B to 10 CFR 50 states:

" Activities affecting quality shall be prescribed by documented instructions, procedures, or drawings, of a type appropriate to the circumstances and shall be accomplished in accordance with these instructions, procedures or drawings.

Instructions, pro-cedures, or drawings shall include appropriate quantitative or qualitative acceptance criteria for determining that important activities have been satisfactorily accomplished."

Operating Procedure No. 10 and Welding Procedure Specification No. 5, Revision 3, require that for pipe fabricated from plate with a wall thickness of one half inch or greater, that the ID seam weld edge bevel must be 5/16 inch in depth.

Contrary to the above, two (2) formed and tack welded, SA-358-1, ASME Section III, Class I, pipes, No. SN9-8351-6P and No. SN9-8351-7P.

having a wall thickness of 1.018 inch, were determined by measuremenu to have ID weld edge seam bevels one fourth inch and less in depth.

4 8010200

\\W