ML19338G330

From kanterella
Jump to navigation Jump to search
Forwards QA Program Insp Rept 99900718/80-01 on 800710-11 & Notice of Deviation
ML19338G330
Person / Time
Issue date: 07/29/1980
From: Potapovs U
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Jonathan Brown
AFCO STEEL
Shared Package
ML19338G331 List:
References
REF-QA-99900718 NUDOCS 8010290101
Download: ML19338G330 (2)


Text

.

UNITED STATES

/p MGu,'o,,

e NUCLEAR REGULATORY COMMISSION O\\

REGloN IV n

7 f d o

611 RYAN PLAZA DRIVE. SulTE 1000

7. E '

8 ARLINGTON, TEXAS 76012 29 JUL 1980

+....

Dockst No. 99900718/80-01

-a AFC0 Steel ATTN; J. W. Brown Executive Vice President P. O. Box 231 Little Rock, Arkansas 72203 Gentlemen:

j This refers to the QA Program inspection conducted by Mr. Ross L. Brown of this office on July 10 and 11, 1980, of your facility at Little Rock, Arkansas, associated with the fabrication of structural steel and miscellaneous steel fabrication and to the discussions of our findings with Mr. R. B. Nelson and members of your staff at the conclusion of the inspection.

This inspectim was made to confirm that, in the areas inspected, your QA Program is being affectively implemented. The inspection effort is not designed to assure that uniqae quality requirements imposed by a customer are being implemented; nor to assure that a specific product, component or service provided by you to your customers, is of acceptable quality. As you know, the Nhc requires each of its licensees to assume full responsibility for the quality of specific products, components or services procured from others.

You should therefore not conclude that the NRC's inspection exempts you from inspections by an NRC licensee or-his agents nor from taking effective cor-rective action in response to their findings.

Areas examined and our findings are discussed in the enclosed report. Within these areas, the inspection consisted of an examination of procedures and representative records, interviews with personnel, and observations by the inspector.

During the inspection it was found that the implementation of your QA Program failed to meet certain NRC requirements. The specific findings and references to the pertinent requirements are identified in the enclosures to this letter.

j Since corrective and preventative actions were taken and verified before the conclusion of this inspection, no further writton response is necessary.

801029 0 log

AFC0 Steel In accordance with Section 2.790 of the Commission's " Rules of Practice,"

Part 2, Title 10, Code of Federal Regulations, a copy of this letter with enclosure and your reply, together with the enclosed inspection report will be placed in the Commission's Public Document Room.

If this report contains any information that you believe to be proprietary, it is necessary that you make a written application within thirty (30) days to this office to withhold such information from public disclosure. Any such application must include a full statement of the reasons on the basis of which it is claimed that the informa-tion is proprietary, and should be prepared so that proprietary information identified in the application is contained in a separate part of the document.

If we do not hear from you in this regard within the specified period, the report will be placed in the Public Document Room.

Should you have any questions concerning this inspection, we will be pleased to discuss them with you.

Sincerely,

(

I l

,9 U'.disPotapovs,kh Vendor Inspection Bran:h

Enclosures:

l.

Notice of Deviation 2.

Inspection Report No. 99900718/80-01

,,..