ML19338E551

From kanterella
Jump to navigation Jump to search
Forwards Addl Questions Necessary to Complete Review of 760607 Requalification Program for Licensed Operators & Senior Operators.Until Review Is completed,740405 Approved Program Still in Effect
ML19338E551
Person / Time
Site: Dresden, Quad Cities, Zion, LaSalle  
Issue date: 10/05/1976
From: Collins P
Office of Nuclear Reactor Regulation
To: Bolger R
COMMONWEALTH EDISON CO.
References
NUDOCS 8010030315
Download: ML19338E551 (5)


Text

_.

y.

s g

DISTRIBUTION:

OLB Reading File D OF B76 OLB Facility File RJCampbell PFCollins RJBursey RRPowell 50 d,50-237, 50-249, 50-254, 50-265, 50-295, Docket i:os. 50-10 50-373, and 50-374 PW0'Connor

=

WEConverse

+

RDSilver GZech Cor:nonwealth Edison Company Docket Files ATTH:

Mr. R. L. Bolcer, PDR Assistant Vice President Local PDR P. O. Box 767 I&E(3)

Chicago, Illinois 60693 OELD ACRS (16)

Gentlemen:

TBAbernathy JRBuchanan

c have re iewed the proposed revised Dresden, Quad-Cities, Zion and LaSalle County Stations "Requalification Program for Licensed Operators, Senior Operators and Senior Operators (Licited)", submitted on June 7, 1976.

Based on our review, we have determined that the additional infomation indicated in Attachment A is necessary for us to complete our review. The enclosure also indicates our position relative to each outstanding issue.

Until our review is completed, the approved program as subnitted April 5,1974 i still in effect at the Dresden, Quad-Cities and 4

Zion Stations and shall be used for requalification training.

Sincerely,

~

ORIGINAL SIGNED BY P. F. COLLINS

=

Paul F. Collins, Chief Operator Licensing Branch Division of Project i4anagement

=

Enclosura:

' " a cW~ * '* '

9 g j\\102 }. k m

p9 I

cc:

Sec next page g

~

//

.?

DOR:0RB1 Pil:0LB N H GZech@$- PFCollins H

f G l- )%}

./

10/q/7Y 70/f/76 W

d

[P:':Cu:,C M PM:0LE h,

PM:L1lE 4

. ! D3E:07.2: I Qg 39:

jgu=s
6 usunek

\\ Rr=a..av l =,;a Conne

.S(%g2

....c w q.

,.C.../l7i 1_._.m.. r ni w QE m 3,5 T

, ic;

  • / 'i

- C.L *;n i hr.. M); AJCM 0;+0 2 u. s novenmus=r eme=Tesa oneca i.,a.se sea a

8010030 3/5-A-

p.

+

,,j_

. Commonwealth Edison'Co. -

_. ~ ~

Reddicks Public Library i

cc:. Mr. John W. - Rowe.

100 West Lafeyette Street-Isham,-Lincoln & Beale.

Counselors.at Law Ottawa, Illinois 61350 1

One First National Plaza, 42nd Floor

==

+?

Chicago, Illinois 60603

.=

~-

Anthony Z. Roisman~, Esquire Roisman, Kessler and Cashdan 1712 N Street, N. W.

=

'Lashington, D. C.

20036 Morris Public Library 604 Liberty Street

+

Morris, Illinois 60451 Mr. ' Charles Whitmore

?

.m President and Chairman Iowa-Illinois Gas and i

' Electric Company 206 East Second Avenue

~

Davenport, Iowa 52801 Moline Public Library l

50' - 17th Street Moline, Illinois-61265 Ro_ art J. Vollen, Esquire 7

109 North Dearborn Street

-Chicago, Illinois 60602 2

Dr. Cecil ~Lue-Hing Director of Research &- Development Metropolitan Sanitary District of Greater Chicago 100 East Erie Street Chicago, Illinois 60611-Waukegan Public Library 128 North County. Street Waukegan, Illinois-60085 i

i i

Richard -E. Powell, Esquire Isham, Lincoln &'Beale One-First National Plaza, Suite 2400

P=
Chicago, Illinois 60670 t

+

d w

e www

--vr v

s A

-w

i Attachment A 4

Questions regarding the Operator Requalification Program Revisions for COMMONWEALTH EDIS0N COMPANY DRESDEN, QUAD-CITIES, ZION AND 1ASALLE STATIONS 1

1.

Section 2, Item A allows for three days of-training per year. at a

~

simulator. for each licensed individual. Our position is that these three training days shall be consecutive.

2.

Section III, Item B allows for the reduction of the three previously

~

required plant control manipulations on Dresden Unit No.1.

Our position is that the revised program shall include the original requirement of three Unit 1 plant control manipulati,ons.

3.

Section IV, Item A.1 allows for administering the annual written examination in a maximum of four individual examinations.

Der i

position is that dividing the annual written _ examination into over-two parts is not acceptable.

This examination may be administered as two examinations to be given within a three month period.

If the examination is administered in two parts, the annual grade will be the average of the two quarterly grades.

4.

Section IV, Item A.3 requires individuals to attend lectures on subjects when his grade is less than 80% on that subject on the annual l

examination.

Our position.is that periodic quizzes shall be administered.

[

t at the end of a lecture or series of lectures on the subjects listed in Section I, A-G.

If an individual receives a grade of less than 80% on these quizzes then additional training shall be administered.

t I

I o

-- i

7 Comonwealth Edison Co. 5.

Section IV, Item A.4 includes the requirements for relieving a individual from licensed duties if his grade is less than 70% on the annual written examination. We believe that this item should be amended to provide for the administration of an oral examination.

Tnis oral examination shall be administered within 14 days of the determination that the operator or senior operator has received a grade of less than 70%.

If an individual demonstrates that he can operate the plant safely, he may be permitted to continue performing licensed duties while participating in an accelerated requalification program.

An individual who fails to demonstrate th'at he can operate the plant safely shall be relieved of all duties requiring the use of his license and shall participate in an accelerated requalification program.

He may return to his licensed duties following completion of requalification training which shall also include a grade of not less than 70% on the written re-examination.

6.

Section IV, Item B allows for exemption of certain individuals from the annual examination.

Our position is that a maximum of two licensed individuals per station will be exempt from taking any annual written examination, provided these individuals are directly invo ved in the preparation and grading of the examination.

The program shall specify who, by title, may be exempt.

7.

Certain sections of the revised program contain the words will and shall.

Our position is that the word "shall" denotes a requirerent; the word "should" denotes a recomendation; and the word "may" cenc:es

J Commonwealth Edison Co..

permission,' neither a requirement nor & recommendation.

Please review the proposed change so'that wording is consistent with the'above.

8.

Section V, Item B provides for the review of applicable procedures and changes ~ to procedures and facility design. The' revised program indicates that this review will be accomplished in a three day period every year.

It is our position that these procedures also shall be reviewed on a continuing basis and that design and procedure changes shall be promptly reviewed by these licensed individuals as these changes are implemented.

9.

Section IV, Item C provides for training of licensed individuals who are not normally at the stations.

This item should be deleted from the subject program since a separate training program for these personnel was approved on September 15,1976.

10. Attachment A,' Item 8 allows credit for a plant control manipulation when fuel is moved over the core.

This item should'be revised so that credit is given only when fuel is moved within the core.

O