Forwards Revision 1 to IE Bulletin 80-19, Failures of Mercury-Wetted Matrix Relays in Reactor Protective Sys of Operating Nuclear Power Plants Designed by C-E. Written Response Required
ML19338E157
Person / Time
Site: Arkansas Nuclear  
Issue date: 08/15/1980
From: Seyfrit K
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Cavanaugh W
ARKANSAS POWER & LIGHT CO.
References
NUDOCS 8009240735
Download: ML19338E157 (1)


Text

r apag -

~

~ /

UNITED STATES

  • [ Y ("e.c ),j

. NUCLEAR REGULATORY COMMISSION TRAL FILES

+:

,.j REGION IV LPOR

' S,

/

art.INGToN, TEXAS 76012 A

611 RYAN PLAZA DRIVE. SUITE 1000

~

=#

,. y August 13, 1980 NSIC Docket Nos.

50-313 50-368 Arkansas Power and Light Company ATTN:

Mr. William Cavanaugh III Vice. President of Generation and Construction P. O. Box 551 Little Rock, Arkansas' 72203 Gentlemen:.

SUBJECT:

II SULLETIN No. 80-19, REVISION 1 - FAILURES OF MERC'JRY-WETTED MATRIX RELAYS IN RZACTOR PROTECTIVE SYSTEMS OF CPERATING NUCI. EAR POWER PLANTS DESIGNED BY CCMBUSTION ENGLNEERING Enclosed is Revision 1 to II Bulletin No. 80-19.

The revision merely clarifies the areas of concern;-therefore, the actions including dates of reports required by you with respect to your nuclear power facility are not changed.

In order to assist the NRC in evaluating the value/ impact.of each Bulletin on licensees, it would be helpful if you would provide an estimate of the nanpower expended in conduct of the review'and preparation of the report (s) required by the Bulletin. Please estimate separately the nanpower associated with correc-tive actions necessary following identification of problems through the Bulletin.

N Should you have any questions regarding the revised Bulletin or actions required by you, please contact this office.

Sinceral,

a N

I!

3.V.Seyfrit//

Director

Enclosures:

1.

II 3u11 etic. No. 80-19, Revision 1 2.

List of Recently. Issued

'IE Sulletins 1

cc: James P. O'Hanlon,. Plant Manager i

Arkansas Nuclear One

.P. O. Box.608 t-Russellville, Arkansas 72801 l

""093.4e 73 5 ;

SSINS No.: 6820 UNITED STATES Accession No.:

NUCLEAR REGULATORY COMMISSION 8006190052 0FFICE OF INSPECTION AND ENFORCEMENT m-e WASHINGTON, D.C.

20555 D

- gf, 29 ev.

22. e9 IE Bulletin No. 80-19 Revision 1 Date: August 15, 1980 Page 1 of 2 FAILURES OF MERCURY-WETTED MATRIX RELAYS IN REACTOR PROTECTIVE SYSTEMS OF OPERATING NUCLEAR POWER PLANTS DESIGNED BY COMBUSTION ENGINEERING BACKGROUND:

This bulletin addresses the failures of mercury-wetted relays used in the logic matrix of the reactor protective system (RPS) of nuclear power piants designed by Combustion Engineering (C-E).

Except for Arkansas Nuclear One Unit 2 and Palisades, both of which use dry-contact matrix relays, the NRC understands that all other operating C-E plants use C.P. Clare Model HG2X-1011 mercury-wetted matrix relays in the RPS.

Mercury-wetted matrix relays manufactured by the Adams and Westlake Ccepany were initially used in the Palisades plant; however, because of repeated failures of these relays, they were subsequently replaced with relays having dry-contacts.

GTE, the manufacturer of these dry-contact relays, however, has since discontinued their production.

Thus, although the dry-contact relays used at Palisades have performed without a failure since they were installed, they are not available for the other operating nuclear power plants designed by C-E.

OPERATING EXPERIENCES AND EVALUATION:

To date, operating nuclear power plants designed by C-E have reported' thirty-one (31) failures of mercury-wetted relays used in the logic matrix of the RPS.

Most of the reported failures were " failed-closed" type (i.e., the type that could inhibit a reactor trip), and four of the reported events involved multi-ple failures (i.e., three relay failures were detected during two tests; two other failures were detected during two different tests).

Because of the re-dundancy within the RPS, no reported event would have prevented a reactor trip; however, the build-up of coincident " failed-closed" failures of certain sets of relays could result in trip failures for off-normal events.

The number of single and multiple relay failures reported gives rise to two (1) the total number of failures yields a much higher random failure concerns:

te than that used in other relay failure estima:c.s*, and (2) the number of 6

5 Other relay failure estimates include (1) WASH-1400, " Reactor Safety Study",

NRC, October 1975; (2) IEEE Std 500-1977,"IEEE Guide to the Collection and Presentation of Electrical, Electronic, and Sensing Component Reliability Data for Nuclear Power Generating Stations", IEEE, New York; and (3) NUREG/

CR-0942, " Nuclear Plant Reliability Data System, 1978 Annual Reports of Cumulative System and Component Reliability", NRC.

IE Bulletin No. 80-19 Revision 1 Date:

August 15, 1980 Page 2 of 2 multiple failures detected suggests the presence of a common-mode failure

- mechanism.

Such a common-mode failure mechanism.could result in the build-up of specific " failed-closed" failures which, in turn, could result in antici-pated transients without scram'(ATWS).

Thus, the relatively high random failure rate and_the suggested common-mode failure mechanism, indicate that

- plants using mercury-wetted matrix relays in the RPS are more susceptible to scram failures than predicted in other studies.

ACTIONS TO BE TAKEN BY HOLDERS OF CONSTRUCTION PERMITS OR OPERATING LICENSES FOR NUCLEAR POWER FACILITIES:

1.

Review your facility to determine whether C.P. Clare Model HG2X-1011 R1 mercury-wetted relays are used in the logic matrix of the RPS.

If R1 no sucn relays are used, you should submit a negative' declaration to this effect and you need not respond to the remaining items in this bulletin. Your negative declaration shall be submitted to the appropriate NRC regional office within thirty (30) days of the date of this bulletin and a copy forwarded to the Director, Division of Reactor Operations

' Inspection, Office of Inspection and Enforcement, NRC, Washington, D. C. 20555.

2.

Licensees of operating facilities using the above talays in the logic R1 matrix of the RPS should increase the frequency of their surveillance R1 tests.

Until further notice, or until the mercury-wetted relays have been replaced with qualified relays of a different design, surveillance testing of the relays:shall be initiated within ten (101 days of the date of this bulletin and repeated at intervals not exceed.ng ten (10) days thereafter..The additional surveillance - testing applies when op' rability R1 e

of_the RPS is required by the Technical Specification.

Upon detecting a R1

~ failed relay, the failed unit shall be replaced with a qualified dry-contact' relay ~or a new mercury-wetted relay.

(The removed relay shall not be_ reused in the RPS.)

3.

Nuclear power-facilities which are using or whose design includes the use of the above relays-in the logic matrix of the RPS shall' submit either R1 their plans and schedules for replacing the mercury-wetted relays with qualified' relays of a different design, or justification for using the mercury-wetted relays. Responses to this item shall be submitted to the

" offices listed in Item 1, above,.within ninety (90) days of the date of the original version of this bulletin, July 30, 1980.

R1

-Approved by-GAO, B180225 (R0072); clearance expires July 31, 1980.

(Application for renewal.pending before~GA0.) Approval was given under a blanket clearance specifically~for identified. generic problems.

a

-,._s',

_____-%,e eh A

1 IE Bulletin No. 80-19 July 31, 1980 RECENTLY ISSUED IE BITLLETINS Bulletin -Subject Date Issued Issued To No.

'80-17 Failure of 76 of 185 7/3/80 All BWR power reactor Control Rods to Fully facilities holding Insert During a Scram Operating Licenses (OLs) l at a BWR or Construction Permit (CP)

Sup. 1 Failure of Control Rods 7/18/80 All BWR power reactor l

to 80-17 to Insert During a Scram facilities holding Operating at a BWR Licenses (OLs) or Con-struction Permits (cps)

Sup. 2 Failures Revealed by 7/22/80 All BWR power reactor to 80-17 Testing Subsequent to facilities holding Failure of Control Rods Operating Licenses (OLs) to Insert During a Scram or Construction Permits at a BWR (cps) 80-18 Maintenance of Adequate 7/24/80 All PWR power reactor Minimum Flow Thru Centrifugal facilities holding OLs Charging Pumps Following and to those PWRs Secondary Side High Energy nearing licensing Line Rupture 80-19 Failures of Mercury-Wetted 7/31/80 All nuclear power Matrix Relays in Reactor facilities having i

Protective Systems of either an Operating l

Operating Nuclear Power License (0L) or a Plants Designed by Combus-Construction Permit (CP) tion Engineering I'

80-20 Failures of Westinghouse 7/31/80 To each nuclear Type W-2' Spring Retut power facility in to Neutral Control your region having Switches an Operating License

.(OL) or a Construction l

Permit (CP)

Enclosure l

I'

_