M

)

1{

[ZC

((

'o,,

UNITED STATES NUCLEAR REGULATORY COMMISSION n..

ij REGION I 4

631 PARK AVENUE 4

g KINO OF PRUSslA, PENNSYLVANIA 19406

+....

September 12, 1980 Docket No. 50-29 Yankee Atomic Electric Company ATTN:

Mr. James A. Kay Senior Engineer - Licensing 25 Research Drive Wastborough, Massachusetts 01581 Gentlemen:

The enclosed IE Information Notice No. 80-32, " Clarification of Certain Requirements for Exclusive-use Shipments of Radioactive Materials," is forwarded to you for information.

No written response is required.

If you desire additional information regarding this matter, please contact this office.

Sincerely, oyce H. Grier Director

Enclosures:

1.

IE Information Notice No. 80-32 2.

List of Recently Issued IE Information Notices CONTACT:

H. W. Crocker (215-337-5217) cc w/encis:

H. Autio, Plant Superintendent J. L. Tribble, President l

l 800g240 33 g

1 SSTNS: 6370 Accession No.:

/

8006190044

[

IN 80-32 UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 August 29, 1980 IE Information Notice No. 80-32:

CLARIFICATION OF CERTAIN REQUIREMENTS FOR EXCLUSIVE-USE SHIPMENTS OF RADIOACTIVE MATERIALS

\\

Background

In mid-1979 the NRC initiated on enhanced program for inspection of shipments of radioactive materials, including, in particular, low level wastes.

In con.1unc-tion with this effort, civil penalties have been assessed for violation of associated regulatory requirements.

IE Bulletins 79-19 and 79-20, " Packaging of Low Level Radioactive Waste for Transport and Burial," issued August 8, 1979 and IE Information hotice 79-21, " Transportation and Commercial Burial of Radioactive Material," issued September 7,1979, provide background in this regard.

During the past year, this augmented inspectio.n/ enforcement program has prompted a number of questions on the proper application of certain regulatory requirements.

These questions involve mainly the problems and deficiencies associated with exclusive use highway shipments of low-level radioactive wastes.

The purpose of thh Notice is to discuss the questions and clarify the applicability of certain requirements.

Aeolication of 49 CFR 173.393(i) and ( H Numerous questions involve the application of the limits of radiation levels of exclusive use shipments as prescribed in 49 CFR 173.393(j).

As stated therein, the regulation reads (j)

Packages for which the radiation dose rate axceeds the limits specified in paragraph (i) of this section, but does not exceed at any time during transportation any of the limits specified in para-graphs (j)(1) through (4) of this section may be transported in a transport vehicle which has been consigned as exclusive use (except aircraft).

Specific instructions for maintenance of the exclusive use (sole use) shipment controls must be provided by the shipper to the carrier.

Such instructions must be included with the shipping paper information:

(1) 1,000 millirem per the package (closed (2) 200 millirem per ho the car or vehicle Entire document previously entered into system under:

ANO SON S N

No. of pages:

3

m-49 CFil 173.303(jl.10 murm/hr 19 CFil 173.393(1).10 mrt m/hr 2 y @r AT ANY POffJT 2 m (G II)

'2 O

AT AtJY POlfJT 2 m (G It)

FilOM Tile VEllTICAL PLANES Pl10JECTED' FilOM Tile VEllTICAL PLAtJE PHOJECTED I'

11Y Tile OUTEll LATEll AL SURFACE lfilOM Tile OUTEll EDGES OF VElllCLE.

a OF Tile Call On VElllCl.E. 200 mrem /hr l 2 miem/hr Iti CAD.

(

/

AT AtJY ImifJT Ot1 Tile EXTElltJALF~

49 CFR 173.393(i).200 mrem /hr f

i Of1 Tile EXTEllf1AL SURFACE 0,F

[

J.

1[(

SullFACE OF Tile Call Oil pl M"

Tile PACKAGE.10 miem/hr.

i l

VElllCLE.1000 mrem /hr

%gyb go q,

W

- ()

l N [0 d [F AT 3 It FilOM Tile EXTEntJAL 4

p CESSIll EX ElltJAL

/ (

SURFACE OF Tile

' ' ' gO PACKAGE. 2 mee.n/hr ;

gd,fP

- ~

IN CAD.

~ ~ ~ ~ ~ ~ ~

J q

SunFACE OF Tile PACKAGE.

A

,Ofg 7

k r

(

1 fr j

i

"-" W,

'/

2c:o, JV

/

\\

g N

sy c(

\\

\\ gy\\

(C

)

,t

\\

/

I

/

A

/

/

,s

/

N

/

FJOTE: 200 mrom/hr 8

/]

IO I T

7s

LIMIT ALSO APPLIES i 0,,,'

{

s AT UtJDEllSIDE OF y

VElllCLE.

EXCLUSIVE-USE CLOSED TRANSPORT, EXCLUSIVE-USE OPEN TRANSPORT 49 CFil 173.393(il-200 mrem /hr

! AT AfJY POltJT OfJ Tile EXTEnfJAL.

APPENDIX A

,5UllFACE OF TIIE PACKAGE.

' " ^ " *,,

/ )L i

IE INFORMTION NOTICE 8) 32 W

'lCCES iiEt'" ^EeiltlA

\\

E I

.SUllFACE OF Tile e

g y

PACKAGE.

t s

+#4, P

RADIATION :

M5

/ CD'

! LIMITS RE

?O 0

I e

NOTE:

4r TOTAL Tl IS NOT tJOTE:

TO FXCEED 50 PER !

. STOWAGE OF PACKAGES 49 CFR 173.393(i) AND.'(j) 49 er il 177.042(a).

(

WITillfJ VElllCLE MUST COMPLY WITil 49 CI'll 177.042(bl, NON-EXCLUSIVE-USE OPEN OR CLOSED

,m

,-,c.,m.,.-

I APPENDIX B IE INF0lVMTION NOTICE F2 WHAT COMPRISES THE PACKAGE ?

40 CFR 171.I1 DEFINES PACK AGING SUCll TilAT YOU MUST CONSIDER THE

.. ASSEMilLY OF ONE OR MORE CONTAINERS AND ANY OTilER COMPONENTS NECESSARY TO ACillEVE COMPLIANCE WITil Tile MINIMUM PACKAGING R EQUIR EM ENTS.,':

~

THEREFORE:

' INNER ASSEMBl.Y' OUTEll ENCLOSURE ENTlilE OUTER IS A PERSONNEL A5 SEMBLY is ENCLOSURE IS " PACKAGE" "'

RARRIER OR SIMULATED

" PACK AG E" IS A SillELD

" CLOSED VElllCLE" A

worm l-

-~

/CoXoY._,

gg

/g'

@@N c=o

' IN Tills SCENARIO, Tile INNER

'IN Tills SCENARIO, Tile U

PACKAGINGS MAY BE CONSIDERED ENTIRE ASSEMBLY (OUTER SillELD g

TO BE Tile " PACKAGE",PROVIDED PLUS INNEli PACKAGINGS) MUST Tile OUTER ENCLOSullE IS NOT BE CONSIDERED AS Tile ** PACKAGE",

{c--J i

NECESSARY TO AClllEVE COMPLIANCE

' SINCE Tile OUTER SillELD IS WITil Tile RADIATION LEVEL LIMIT I

NECESSAFlY TO ACHIEVE COMPLIANCE

, OF 173.393(jl{2);l.e.,200 mrem /hr+

I WITil 173.393(ll(2). IIADIATION LEVEL OF RADIATION ON EACilINNER l LEVEL AT SURFACE OF **lNNER" g

" PACKAGE"MAY NOT EXCEED 1 rem /hr ATI l PACKAOlNGS IS NOT LIMITED.

,3 f t FilOM ITS SUllFACE..

W b

e IE Information Notice No. 80-32 September 12, 1980 RECENTLY ISSUED IE INFORMATION NOTICES Information Subject Date Issued to Notice No.

Issued 80-31 Maloperation of Gould-8/27/80 All holders of Brown Boveri 480V-Type a power reactor K-6005 and K-DON 6005 OL or CP Circuit Breakers 80-30 Potential for Unaccept-8/27/80 All holders of able Interaction a BWR power reactor Between the Control OL or CP Rod Drive Scram Function and Non-essential Control Air at Certain BWR Facilities 80-29 Broken Studs on 8/7/80 All holders of Terry Turbine a power reactor Steam Inlet Flange OL or CP Supplement Notification of 7/29/80 All holders of a to 80-06 Significant Events power reactor OL at Operating Power and near term OL Reactor Facilities applicants 80-28 Prompt Reporting 6/13/80 All applicants of Required Information for and holders To NRC of a power reactor construction permit 80-27 Degradation of Reactor 6/11/80 All holders c Coolant Pump Studs a pressurized ; ater power reactor OL or CP 80-26 Evaluation of 6/10/80 All holders of a Contractor QA Part 50 License Programs 80-25 Transportation of 5/30/80 Material Licensees Pyrophoric Uranium in Priority / Categories II-A, II-D, III-I and IV-DI; Agreement State Licensees in equivalent categories