ML19338D865

From kanterella
Jump to navigation Jump to search
Contract:Followon to Simulation of Earthquake Ground Motions for San Onofre Nuclear Generating Station, Awarded to R Hermann
ML19338D865
Person / Time
Site: San Onofre  
Issue date: 08/28/1980
From: Hermann R, Perlman J
NRC OFFICE OF ADMINISTRATION (ADM), ST. LOUIS UNIV., ST. LOUIS, MO
To:
Shared Package
ML19338D862 List:
References
CON-FIN-B-6898, CON-FIN-B-6898-0, CON-NRC-03-80-145, CON-NRC-3-80-145 NUDOCS 8009240057
Download: ML19338D865 (5)


Text

[5',,5'f,d$.OCE..haR, i..th..r'ik..

AWARD /C2NTRACT

'[ I

/,

-,. esx r

CC,.%,,,

iz u. Is,,. s NO.

2. EnECnvt cart

,hPC-03-80-145 AUG 2 81980 RFPA NRR-80-145

%'Gi"'

i 3. REWl5dCNWRCMa&E REWE$UaOMCT NO.

4. CERTitED FC N/J@NM DUENSE UNDH SQ5A A

[ 15%E0 Sy CODE' e, ADMINISTERED Sf US Nuclear Regulatory Commission (if oth,r than blank 9)

CODE l3

7. DEuvERY 0 ~ FOS DEsti.

A ro~

Oivision of Contracts, SPS Washington, DC 20555 OTufn (5,,

0 6eu->

8 CONrnacicR CoDEI I

raCstsiv v>DE j

9. DisCOu~r ron P OMPT PAYMENT NAME AND ADDRESS l

Dr. Robert Herrmann 2.'"',I "'li,.

c/o St. Louis University NA e: m.o.u)

PO Box 8099 St. Louis, M.0 63156 io. susMir invoices,Ess 3nOwN,N TOC,..u,, e o cop,,t

,pm,f,,s; TO.oD 1

II. $ HIP TO/ MARK FOtt CODEj j

12. PAYMENT WILT BE MADE BY CODE l US Nuclear Regulatory Commission US Nuclear Regulatory Commission AlTN:

Dr. Robert aackson Office of the Controller NRR, Division of Engineering Washington, DC 20555 Washington, DC 20555 THIS PROCUpfMENT WA1 O AovEaristo. D~EcCriArEo. *uasuA~110,

] TD L15.C. 2304 (oX )

13 X di U3 C. 252 (cx 3i I d. ACCOUNTING AND APPROPRIAfiON DATA B&R Ho.:

20-19-05-05 FIN No.: B-6898-0 App ro'priation:

31X0200.200 - $5,000.00 13 16.

IT E M NO 17, 18.

19.

20.

$UPPLIE 5 / 5E RvlCES Q U A NTIT Y UNIT UNIT PRICE AMOUNT l Follow-on To Simulation of Earthquake Ground l Motions for San Onofre Nuclear Generating

! Station i

$5,000.00

+

a 21.

TOrAt AMOUNT OF CONTRACT $

$5,000.00 CONTRACTING OFFICER frill COSIPLETE BLOCK 22 OR 26 AS APPLICABLE

22. h CONTRACTOR'S HEGOTIA,ED AGREEMENT (Centracter is r,quir,d to s.gn 26.

AWARD (Centracter is not r,quir.d to sign this docum,er.)

3 vast on,

shis elocan,nt and rytern copi,n to issuing efw,.) Contractor ogress en Soluc.tohon Number e

9n furn sh and del.ver all items or perforen oil the serv.ces set forth or otherwise

including the identded above and on any seatinwohon sheets for the seasiderotion stated beeevi.

add.hons or chen0es made by yov which oddet.ons or changes are set forth in full The e.gh,s and obhgotions of the porties to this contract shall be subiect to and gov-obove, is hereby occepted as to the items hated obove end on any continuat on shoes.

eteed by the following docwmeses. (o) this wword/ contract, (b) the sehcstohon, of ony, This award consummates the sentract which consists of the following documents: (o) and io suts,,ov.s.o,s.,e,,esentor.or.s. ce, tac.ons the Government's sehcetohon end yons oRet, and (b) this eword/ contract. No

.n..hed.c.n.,rg.t.d,, r.f.een.g.,

< s.....nd s,oa,cosons,, os, ro v.,,t%e cent,oct i do. ment is necess.tr.

.e..,s. -

d,,,.,

n n

2. N.-E e yA.J b,_ n 7Am 2

O.

2,..N.,ot,O,AME CA

- w xn

(,,n._.I es.n sed M s..n, f;

i

,s.gn.t.re o, C_.c,.ng Ose,

24. NA E AND TITLE OF SIGNER (Typ, er print)
25. DATE $1GNED
28. NAME OF ONTRACT:NG OFFICER (Typ, er pries)
29. DATE SIGNED j

j o,3m B, Ntamw 6/so a0v e etRtMAN r 2 r/'m

u. t.

U.S. GOVERNMENT FRINT ING OFF I CE: 1976 200= 988

$009240 Q57

.a

V NRC-03-80-145 Page 2 of 5 ARTICLE I - BACKGROUND In order to detennine the proper level of earthquake ground motion (response spectrum) to be used in the seismic evaluation of the San Onofre Generating Station, Southern California Edison has carried out a series of state-of-the-art studies that numerically estimate this ground motion from a rupturing fault near the site. A panel reviewed these reports for the NRC and made recommendations as to their general validity and usefulness in specifying the appropriate ground motion.. Subsequent to the writing of these reports, the October 1979 Imperial Valley Earthquake occurred and yielded the most extensive set of data yet recorded in the near field of a magnitude 6.5 to 7.0 event.

Southern California Edison was asked to conduct a series of studies that would attempt to further validate their numerical model and ground motion estimates by testing this model with respect to the Imperial Valley data.

ARTICLE II - SCOPE OF W0k Task 1.

Review of Report Review the applicant's study of the 1979 Imperial Valley Earthquake with respect to general validity, validity of assumed earthquake ground motion model, and impact upon previous evaluations of ground motion studies.

Prepare and submit a technical evaluation of the study.

Task 2.

Follow-on Review Upon completion of Task 1, review and evaluate additional information submitted by the applicant in response to questions raised in the technical evaluation performed under Task 1.

Prepare and submit technical evaluations of additional information submitted.

Task 3.

Participation in Meetings and Hearings Attend four meetings to discuss the specified ground motion level.

Prepare necessary testimony or discussion material for these meetings. These meetings will be with the applicant, the NRC' staff, and the Advisory Comittee on Reactor Safeguards (ACRS). Participation in the Atomic Safety Licer.si'ig Board (ASLB) will be required to testify on related contentions.

ARTICLE III - PERIOD OF PERFORMANCE The period of performance will commence on or before the efiective date of this contract, and all effort shall be completed within fourteen months.

. I ARTICLE IV - CONSIDERATION In full-consideration of the Contractor's performance hereurider, the NRC shall pay the Contractor at the rate of $182.00 per day, estimated to be twenty-five (25)mandays. The Contractor will be reimbursed an amount not to exceed $1600.00 m

&e e.

y ee*M-+4

'**bhe-*

-em4e,

.gg>gg. y

=w.

4*

-=ea**

-==, e -u.e

+

= = -

  • m-*

= er. ? >ogne

=_.4m_ee

.A

~

s NRC-03-80-145 Page 3 of 5 for all travel as described below, incurred directly and specifically in the performance of this contract, claimed by the Contractor and accepted by the Contracting Officer.

i l-Domestic travel expenses -incurred by the Contractor in direct performance provided such travel is necessary for the performance of this contract and not exceeding:

a.

Cost of air travel by most direct route.

Air Coach" or " Air Tourist" l

accommodations on prop or jet aircraft constitutes the normal class of air travel which shall be utilized.

First-class accommodations may be i'

used if (1) less than first-class is not available providing reservation was requested within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after the traveler had knowledge of the trip; (2) less than first-class requires circuitous routing, (3) less than first-class requires travel to begin or end at unreasonable hours (i.e., if scheduled flight time is before 8:00 AM and scheduled arrival is after 9:00 PM); (4) less than first class would result in additional direct costs which offset the transportation savings; or (5) less than first-class will not make connections with other flights or transportation for continuation of the journey which greatly increc;es the duration of the flight; or (6) less than first-class would offer accommodations which are 4

not reasonably adequate for the physical or medical needs of the traveler.

t l

b.

Cost of rail travel by most direct route; first-class with lower berth or nearest equivalent.

l c.

Travel by motor vehicle including rented automobile shall be reimbursed on a reasonable actual expense basis, or at the Contractor's option on a mileage basis at a rate of 20c per mile plus any toll or ferry charges.

d.

Private vehicle mileage shall be reimbursed at 20c per mile.

Per diem shall be reimbursed at a daily rate not to exceed $50.00 per day.

e.

f.

Recipts are required for common carrier transportation, lodging, and miscellt.neous for any one item in excess of $15.00.

ARTICLE V - OBLIGATIONS The amount presently obligated by the NRC with respect to this contract is

$5,000.00, Additional funds in the amount of $3,000.00 for the second fiscal year will be obligated, subject to the availability of funds, by a unilateral modification to the contract, y

ARTICLE VI - PAYMENT i

Payment shall be made in'accordance with Clause 2 of the General Provisions entitled " Payment" as soon as practicable after completion of all the work and acceptance by the Project-Officer of the final report, upon submission by the Contractor of voucher (s) in a form satisfactory to the Contracting Officer; provided, however, that said payment (s) shall not be deemed to 4

g,

4 4

<w4

= a e en e-e shewe 4 9

'D-M*='--

m'

-n+e-ee-guy p 44de' Y

~

NRC-03-80-145

~

Page 4 of 5 prejudice any rights which the Government may have by law or under other provisions of this contract. Partial payments are authorized upon completion of each Task and acceptance by the Project Officer.

ARTICLE VII - REPORTING REQUIREMENTS

^

Upon completion of Tasks 1 and 2, the Contractor will submit his technical evaluations in letter report form to Dr. Leon Peiter, Division of Engineering, Nuclear Reactor Regulation, NRC, with copies to Dr. Robert Jackson and Mr. James P.

Knight, also of the Division of Engineering, Nuclear Reactor Regulation, NRC.

ARTICLE VIII - GOVERNMENT-FURNISHED MATERIALS A copy of the applicant's study will be provided under separate cover.

ARTICLE IX - SPECIAL PROVISIONS IX.1 PROJECT OFFICER Performance of the work hereunder shall be subject to the technical instructions issued by the US Nuclear Regulatory Commission. The technical instructions shall be signed by the Project Officer.

i The Project Officer is responsible for:

1.

monitoring the Contractor's technical progress, including the surveillance and assessment of performance and recommending to the Contracting Officer changes in requirement; 2.

interpreting the statement of work; 3.

performing technical evaluation as required; 4.

performing the technical inspections and acceptances required by this contract; and 5.

assisting the Contractor in the resolution of technical problems encountered during performance.

Within the purview of this authority, the Project Officer is authorized to approve payment vouchers for supplies / services required under the contract. The Contracting Officer is responsible for directing or negotiating any changes in terms, conditions, or amounts cited contract.

For guidance from the Project Officer to the Contractor to be valid,

'it must:

1.

be consistent with the description of work set forth in this contract; 2.

not constitute new assignment of work or change of the expressed terms, conditions, or specifications incorporated into this contract; e

4m**

w-

-ee-A

NRC-03-80-145 Page 5 of 5

~

3.

not constitute a basis for an extension to the period of performance or contract delivery schedule; and 4.

not constitute a basis for any increase in the contract price.

If the Contractor receives guidance from the Project Officer which the Contractor feels is not valid under the criteria cited above, the Contractor shall immediately notify the Project Officer.

If the Project Officer and the Contractor are not able to resolve the questions within five days, the Contractor shall notify the Contracting Officer.

IX.2 INSPECTION AND ACCEPTANCE Acceptance af the services and reports to be delivered herein will be made by the r roject Officer.

IX.3 DISSEMINATION OF CONTRACT INFORMATION The Contractor shall not publish, permit to be published, or distribute for public consumption any information, oral or written, concerning the results or conclusions made pursuant to the performance of this contract without the prior written consent of the Contracting Officer.

(Two copies of any material proposed to be published or distributed shall be submitted to the Contracting Officer.)

ARTICLE X - GENERAL PROVISIONS The contract is subject to the Fixed Price Research and Development Contracts under $10,000.00, dated November 14, 1977, which incorporates the FPR Changes and Additions and NRC Additions, attached hereto and made a part hereof.

Clause 14 entitled " Patent Rights" is deleted in its entirety.

i f

.e-

- e.... - i

"#E "M

l--

___-_.a 9S

^-

-