AUG 2 61380 Docket No. 50-311 Mr. R. L. Mitti, General Manager Licensing and Environment Engineering and Construction Department PubHc Service Electric and Gas. Company

" 80 Park Place Newark, New Jersey 07101

Dear Mr. Mitti:

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW 0F SALEM 2 FOR A FULL POWER LICENSE As a result of our contiruing review of Salem 2 for a full power license, we find that we need additional information to complete our evaluation. The specific information required is listed in the enclosure. This information was previously telecopied to Mr. Ed Liden.

The enclosed question is in regard to your submittal of July 1,1980, which discusses the auxiliary feedwater source.

To maintain a timely review for the Salem 2 full power ifcense, we will need your response as soon as possible.

If you have any questions about this request, please do not hestitate to contact us.

' '3 Sincerely, Robert L. Tedesco Assistant Director for Licensing Division of Licensing

Enclosure:

As stated cc w/ enclosure:

See next page G

8009I90/3/-

cc: Richard Fryling, Jr., Esq.

Assistant General Counsel Public Service Electric & Gas Company 80 Park. Place Newark, New Jersey 07100 Mark Wetterhahn, Esq.

Conner, Moore & Cober

' Suite 1050 1747 Pennsylvania Avenue, N. W.

Washington, D. C.

20006 Mr. Leif J. Norrholm c/o U. S. Nuclear Regulatory Commission Region I, Drawer I Hancocks Bridge, New Jersey 08038 E

a 9

5 e

q ENCLOSURE REQUEST FOR ADDITIONAL INFORMATION Your submittal of July 1, 1980, has addressed staff concerns about the salt content of the long-term auxiliary feedwater source for Salem, Units 1 and 2.

Show that the discussion presented in that submittal, assuming a 3.5 percent sodium chloride solution, is conservatively bounding for compositions with other dissolved solids. Discuss the potential for heat transfer fouling of the steam generator secondary side due to the presence of dissolved solids other than NACL which are characterized by low solubilities and decreasing solubility with increasing temperature (e.g.,

Ca, Ng, P0j, C0j, S0j).