Forwards LER 80-017/03L-0
Date released: 12/18/2019 Download: ML19338C947


LER 80-017/03L-0:on 800724,during Testing,Pressure Switch PS-2-1622B Was Found to Actuate at 20.3 Rather than 13.8 Inches of Water.Caused by Setpoint Drift.Switch Replaced
ML19338C948
Person / Time
Site: Quad Cities Constellation icon.png
Issue date: 08/12/1980
From: Steffes C
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19338C948 (1)
Forwards LER 80-017/03L-0
ML19338C946
Person / Time
Site: Quad Cities Constellation icon.png
Issue date: 08/13/1980
From: Kalivianakis N
COMMONWEALTH EDISON CO.
To: KEPPLER J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19338C946 (2)