ML19338C582

From kanterella
Jump to navigation Jump to search
Responds to IE Bulletin 79-03A, Longitudinal Weld Defects in ASME SA-312,Type 304 Stainless Steel Pipe. Fusion Welded Pipe Not Used in safety-related Sys at Greater than 85% of Code Allowable Pressure Stress
ML19338C582
Person / Time
Site: McGuire, Mcguire  Duke Energy icon.png
Issue date: 08/05/1980
From: Parker W
DUKE POWER CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
IEB-79-03A, IEB-79-3A, NUDOCS 8008180182
Download: ML19338C582 (1)


Text

_-_

77G Dunn POWEH COhlyg pg.

g.

i Powen Best.ntxo Ti. A N T/s, t[,

422 SocTu Cuencu STarr.T CILAHl.OTTr N. C. 282 52 w w au o.pannen,sa.

b N

WCf PetSiO(NT IEL(PeeQeg[ Ap( A 7 0 4 Sves se Pocouchow 373 4083 August 5, 1980 l

Mr. James P. O'Reilly, Director U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303 Re: RII:JPO I

~

McGuire Nuclear' Station Docket Nos 50-369 and 50-37

' ~ ~ ~ ~ ~

Dear Mr. O'Reilly:

In response to your letter of April 4, 1980 which transmitted IE Bulletin 79-03A, we wish to advise that a review of McGuire Nuclear Station's piping specifications has been conducted. Duke Power Company has not used SA-312, A-312, Type 300 Series fusion welded pipe in safety-related systems at greater than 85 percent of Code allowable pressure stresses. No future use above this limit is planned.

V y truly yours, l

A

.e -

- d /@.bd William O. Parker, Jr.

RWO:vr cc: NRC/0IE Division of Reactor Construction Inspection OFFICIAL COPV f [ f