ML19337B320

From kanterella
Jump to navigation Jump to search
Responds to IE Bulletin 80-16.No Rosemount Model 1151 or 1152 Pressure Transmitters in Use in safety-related Applications
ML19337B320
Person / Time
Site: Seabrook  NextEra Energy icon.png
Issue date: 08/21/1980
From: Devincentis J
PUBLIC SERVICE CO. OF NEW HAMPSHIRE
To: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
IEB-80-16, SBN-132, NUDOCS 8010020082
Download: ML19337B320 (1)


Text

Ti e i Lj PUBLIC SERVICE Company of New Hampshir e SEABROOK STATION Engineering Office:

20 Turnpike Road Westborough, MA 01581 August 21, 1980 SBN-132 T.F. B 4.2.5 U.S. Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, Pennsylvania 19406 Attention: Office of Inspection and Enforcement

Reference:

1. Docket No. 50-443 and 50-444
2. NFC letter dated June 27, 1980
3. IE Bulletin No. 80-16

Subject:

Potential Misapplication of Rosemount Inc. Models 1151 and 1152 pressure Transmitters with Either "A" or "D" Output Codes

Dear Sir:

We have reviewed IE Bulletin No. 80-16 and have determined that no Rosemount transmitters of the type identified in the bulletin are used in safety related applications.cn Seabrook Station.

If you require further information please do not hesitate to contact us.

Very truly yours, i h 94/

John DeVincentis Project Manager DAM: tan 4

80100P00?A g

__