ML19337A486
| ML19337A486 | |
| Person / Time | |
|---|---|
| Site: | 07001308 |
| Issue date: | 08/18/1980 |
| From: | Davis A NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| To: | Vanhoomissen J GENERAL ELECTRIC CO. |
| Shared Package | |
| ML19337A487 | List: |
| References | |
| NUDOCS 8009290090 | |
| Download: ML19337A486 (2) | |
Text
_______
'o, UNITED STATES I/6 e
NUCLEAR REGULATORY COMMISSION g
3,,
g c
REGION lli n
s e
799 ROOSEVELT ROAD g
GLEN ELLYN, ILLINOIS 60137
'AUG 18 860 DocketNo.f-1308 General Electric Company ATTN:
Mr. J. E. Van Hoomissen Manager, Spent Fuel Services Operation 175 Curtner Avenue San Jose, CA 95125 Gentlemen:
This refers to the routine inspection conducted by Mr. C. C. Peck of this office on July 29 - August 1,1980, of activities at Morris Operation authorized by NRC Special Nuclear Materials License No. SNM-1265 and to the discussion of our findings with members of Mr. E. E. Voiland's staff at the conclusion of the inspection.
The enclosed copy of our inspection report identifies areas examined during the inspection. Within these areas, the inspection consisted of a selective examination of procedures and representative records, obser-vations, and interviews with personnel.
No items of noncompliance with NRC requirements were identified during the coucse of this inspection.
In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations, a copy of this letter and the enclosed inspection report will be placed in the NRC's Public Document Room, except as follows.
If this report contains information that you or your contractors believe to be proprietary, you must apply in writing to this office, within twenty days of your receipt of this letter, to withhold such information from public disclosure. The application must include a full statement of the reasons for which the information is con-sidered proprietary, and should be prepared so that proprietary informa-tion identified in the application is contained in an enclosure to the application.
8009290090
General Electire Company EU6 ' 8 G80' 3
We will gladly discuss any questions you have concerning this inspection.
Sincerely, i
A. B. Davis, Chief Fuel Facility and Materials Safety Branch
Enclosure:
IE Inspection Report No. 70-1308/80-04 cc w/ encl:
Mr. E. E. Voiland, Manager Morris Operation Mr. D. M. Dawson, Manager, Licensing and Transportation Fuel Recovery Operations Central Files Reproduction Unit NRC 20b PDR Local PDR NSIC Mr. Dean Hansell, Office of Assistant Attorney
._,