UNITED STATES NUCLEAR REGULATORY COMMISSION O
j WASHINGTON, D. C. 20555
\\
/
SEP 2 31980 FCUP:RLS70-157 SNM-180 The University of Texas College of Engineering ATTN: Dr. T. L. Bauer Supervisor, Nuclear Reactor
~
Laboratory Austin, Texas 78712 Gentlemen:
Our review of your application for renewal of Special Nuclear Material License SNM-180 has revealed a need for updated information concerning I
certain aspects of your safety program. The needed information is
)
identified in the attachment. We will continue our review of your application following receipt of the additional information.
Sincerely,e d
X Robert I.. Stevenson Uranium Process Licensing Section Uranium Fuel Licensing Branch Division of Fuel Cycle and Material Safety
Enclosure:
As stated 8010230#P
~
d
Questions on Renewal Application University of Texas August 27, 1979, Docket 70-157 1.
(a) Please describe the required qualifications of education and experience and the duties of the Radiation Safety Officer.
(b) Who has responsibility for ensuring that the Radiation Safety Officer carries out his duties properly?
2.
Describe the program for limiting exposures of personnel to radiation and for measuring and recording the doses incurred.
3.
Describe the experience and qualifications of Doctors Bauer and Klein relevant to the safe handling of the neutron sources and the special nuc!aar material.
4.
Please describe the system for knowledgeable review and approval of the procedures for experiments to ensure that experiments are conducted safely.
5.
Plea e describe the radiation detection instruments that are used to monitor the operations with radioactive material, including a description of the instruments, the number of each type available, sensitivity range, and provisions for periodic calibration.
6.
Describe the provisions for radioactive waste disposal.
s
!