Notifies That Util 881026 & 1202 Responses Acceptable to Close Out NRC Bulletin 88-009, Thimble Tube Thinning in Westinghouse Reactors
ML19332D966
Person / Time
Site: Point Beach  
Issue date: 11/22/1989
From: Swenson W
Office of Nuclear Reactor Regulation
To: Fay C
WISCONSIN ELECTRIC POWER CO.
References
IEB-88-009, IEB-88-9, TAC-72672, TAC-72673, NUDOCS 8912060086
Download: ML19332D966 (2)


Text

m.,

m s

~'

4 November 22, 1989

%I Docket Nos.' 50-266 :

T i

and 50-301 PDIII r/f R

NRC& Local PDRs JHannon s,.

L w,A

.1 JZwolinski PKreutzer

  • Mr. C. W. F U, Vice President WSwenson OGC J

Nuclear, Power Department EJordan ACRS(10) 0

_aWisconsin Electric Power Company PDIII gray BBuckley 231~W. Michigan Street, Room 308 TMarsh
n > 3, Milwaukee, Wisconsin 53201 y-

[j

Dear'Mr.:

Fay:.

[

k

SUBJECT:

  1. 'POINTBEACHNUCLEARPLANTUNITNOS.1AND2-CLOSE0VT j

0F BULLETIN 88 THIMBLE TUBE THINNING IN WESTINGHOUSE s3, REACTORS (TACNOS.72672AND72673) g(

' Wisconsin' Electric Power Company (WEPCO) responded to NRC Bulletin 88-09, by letters dated October 26, 1988 and December 2, 1988.-

7 Based on our review of your responses, we conclude that the actions a l taken by WEPCO fully respond to the issues identified in the bulletin and are acceptable.

In your responses, you confirmed that a thimble tube thinning inspection program has been implemented for the Point Beach Nuclear Plant. Corrective action consists of capping any thimble tube if cumulative wall loss is predicted to exceed 60 percent before the 4

next inspection.

In order to prolong the life of the thimble-t@e, you indicated that the tube may be repositioned to move the degraded portion of the tube into an area where fretting is not occurring.. Further, you committed to perform future inspections with the time interval between inspections to be determined by the difference between the maximum permissible wall loss and the observed wall loss, divided by the observed wear rate.

.WEPC0 has met the criteria specified in Bulletin 88-09 and has

' reported the results of the inspections in the submittals noted above. Therefore we consider actions relative to Bulletin 88-09 I

l-and TAC Nos. 72672 and 72673 to be complete..

Sincerely, u

/s/

Warren H. Swenson, Project Manager Project D, rectorate III-3 Division of ReactorP rqiects - III, IV, Y and Special Projects Office of Nuclear Reactor Regulation cc: See next page g~,

(

Office:

LA/PDIUI-3 P

I-3 PL/PDIII-3 PDAA aM Surname:. PKritftfer WSwenson JHannos 8 SMU TM

'Date:

.n / g /g y /f /G y /p /d g p

[$16..s,,22 gs) l ADOCK 050 6

r,y ]DR

f l

! l ';

t f d Mr. C. W. Fay Point Beach Nuclear Plant

.-Wisconsil Electric Power Company

' Units 1 and 2 l-cc:

i Mr. Bruce Churchill, Esq..

l Shaw, Pittman, Potts and Trowbridge i

2300 N Street, N.W.

Washington, DC 20037

- Mr. James J. Zach, Manager L

Point Beach Nuclear Plant i

Wisconsin Electric Power Company i

6610 Nuclear Road

+

Two Rivers, Wisconsin 54241 Town Chairman l

Town of Two Creeks Route 3 Two Rivers, Wisconsin 54241 l

Chairmsn Public Service Commission of. Wisconsin Hills Farms State Office Building

)

Madison, Wisconsin 53702 Regional Administrator, Region Ill U.S. Nuclear Regulatory Commission Office of Executive Director

.for Operations 799 Roosevelt Road Glen Ellyn, Illinois 60137 Resident Inspector's Office U.S. Nuclear Regulatory Commission 6612 Nuclear Road Two Rivers, Wisconsin 54241

!