[p[.
l November 27, 1989-i Docket No. 50-320
-Mr. Michael B. Roche L
Vice President / Director L
Three Mile Island Unit 2
[
GPU Nuclear Corporation L
P. O. Box 480 Middletown, Pennsylvania 17057 L
Dear Mr. Roche:
SUBJECT:
THREE MILE ISLAND NUCLEAR STATION, UNIT 2 - SAFETY EVALUATION REPORT FOR THE USE OF THE POLAR CRANE AUXILIARY HOOK OVER THE SEAL e
TABLE (TAC #74594) 6 The Nuclear Regulatory Connission staff has reviewed your October 26, 1989, i
submittal pertaining to the use of the polar crane (PC) auxiliary hook over the incore instrunent seal table. As stated in the enclosed Safety Evaluation issued by the staff, we conclude that the proposed activities can be accom>11shed without significant risk to the health and safety of the public provided t1at they are.in accordance with the limitations stated in your submittal.
L Use of _ the PC auxiliary hook over the seal table to withdraw incore instrument
-strings falls within the' scope of activities previously considered in the staff's "Programmtic Environmental Impact Statement" as supplemented. We, therefore, approve the proposed activities as described in your Safety Evaluation' Report.
Sincerely,
/s/
y L
John F. Stolz, Director o
Project Directort.te I-4 Division of Reactor Projects I/II
._o Jg Office of Nuclear Reactor Regulation
, g$nou.
Enclosure:
ug As stated DFoi L!k cc w/ enclosure:
gg See next page t
. oc.
l Mh.
4.DISTRIBUT:
ON ecastg1He NRC 8 Local PDRs Plant File S.Varga(14E4)
$@o.
L.'Thonus " #, ~ M. Masnik ACRS(10)(14A2)
B. Doger S. Norris OGC E. Jordan (MNBB3302) l l
l Orc :LA: POI-4
- PM:PDI :PM:PDT-4
- PD:(3{-4 NAME :SNorris
- LThonus:Im :MMasnik
- JStol I-----t------------:------------:------------:-----
! DATE : / ;/89_
' / /89
- / /89
- l/ /jjlS9 OFIICIAL RECORD CO T
~
~
Don t-Name: TAC 74594 en
w -
p i
-6
. Mr. M. B. Roche Three Mile Island Nuclear Station GPU Nuclear Corporation Unit No. 2 j
s L
cc:
L Frank Lynch, Editorial Regional Administrator, Region I The Patriot U.S, Nuclear Regulatory Comission 812 Market Street 1
475 Allendale Road Harrisburg, PA 17105 i
King of Prussia, PA 19406 j
Dr. Judith H. Johnsrud Robert B. Borsum Environmental Coalition on Nuclear Power Babcock & Wilcox 433 Orlando Avenue Nuclear Power Division State College, PA 16801 Suite 525 1700 Rockville Pike i
Rockville, MD 20852 i
Ernest L. Blake, Jr., Esquire Marvin I. Lewis Shaw, Pittman, Potts, and Trowbridge 7801 Roosevelt Blvd. #62 2300 N Street, N.W.
Philadelphia, PA 19152 Washington, DC 20037 Secretary Jane Lei.
U.S. Nuclear Pegulatory Comission 183 Valley Road Washington, DC 20555 Etters, PA 17319 Sally S. Klein, Chairperson Walter W. Cohen, Consumer Dauphin County Board of Comissioners Advocate Dauphin County Courthouse Department of Justice Front and Market Streets Strawberry Square,14th floor Harrisburg, PA 17120 Harrisburg, PA 17127 Thomas M. Gerusky, Director Mr. Edwin Kinter Bureau of Radiation Protection Executive Vice President Department of Environmental Resources GPU Nuclear Corporation P. O. Box 2063 100 Interpace Parkway Harrisburg, PA 17120 Parsippany, NJ 07054 s
Ad Crable
-U.S. Environmental Prot. Agency Lancaster New Era Region III Office s
8 West King Strett Attn: EIS Coordinator Lancaster, PA 17601 841 Chestnut Street Philadelphia, PA 19107 U.S. Department of Energy P. O. Box 88
~Middletown, PA 17057 David J. McGoff Francis 1. Young Office of LWR Safety and Technology SeniorResidentInspector(TMI-1)
NE-23 U.S.N.R.C.
U.S. Department of Energy Post Office Box 311 Washington, DC 20545 Middletown, Pennsylvania 17057 y - +
_m~,
i I
,e i
Mr. M. B. Roche Three Mile Island Nuclear Station GPU Nuclear Corporation Unit No. 2 l
I cc:
j i
G. Kuehn R. E. Rogan GPU Nuclear Corporation GPU Nuclear Corporation j
\\
i J. J. Byrne-S.~ Levin
-l GPU Nuclear Corporation GPU Nuclear Corporation b
W. J. Marshall i
GPU Nuclear Corporation l
i
?
i w
S o
l I
5
?
s e
b I'
t
-t i
1 1^
L
_ __.___-;