ML19332D281

From kanterella
Jump to navigation Jump to search
Discusses 355th Meeting of ACRS on 891116-18 Re Draft Suppl 2 to Generic Ltr 88-20, Accident Mgt Strategies for Consideration in Individual Plant Exam Process & Draft Nureg/Cr Rept Re Candidate Accident Mgt Strategies
ML19332D281
Person / Time
Issue date: 11/20/1989
From: Remick F
Advisory Committee on Reactor Safeguards
To: Carr K
NRC COMMISSION (OCM)
References
ACRS-R-1376, GL-88-20, NUDOCS 8911300261
Download: ML19332D281 (2)


Text

.

OMf/376

", n\\

2W7 UNITED STATES ID[

- NUCLEAR REGULATORY COMMISSION n

mT i

ADVISORY COMMITTEE ON REACTOR SAFEGUARDS wAsHWGTON, D. C. 20666 November 20, 1989 t

The Honorable Kenneth M. Carr Chairman U.S. Nuclear Regulatory Comission

. Washington, D.C.

20555

Dear Chairman Carr:

SUBJECT:

DRAFT SUPPLEMENT NO. 2 TO GENERIC LETTER 88-20. " ACCIDENT' MANAGEMENT STRATEGIES FOR CONSIDERATION IN THE INDIVIDUAL PLANT EXAMINATION PROCESS"

.During the 355th: meeting of the Advisory Committee on Reactor Safeguards, November 16-18, 1989, we discussed -the subject document with the NRC staff.

We also reviewed a draft NUREG/CR report entitled, " Assessment of Candidate Accident Management Strategies," that the staff proposes to send as an' enclosure with the supplement to the generic letter.- We had the benefit of these~ documents which are referenced.

Our Subcomittee. on Severe Accidents met on September 20, 1989 to discuss this matter.

We conclude that the information in these two documents will be useful to licensees in the process of performing Individual Plant Examinations, and we agree that the documents should be issued.

The draft NUREG/CR report referred to describes strategies for. accident-management that are said to be PRA based.

However, the report does not

. include information on the risk reduction that might be attributed to the

'strategies.

This information would be useful to those considering the strategies.

We recommend that this information be added if it is rea-L sonably retrievable from existing sources.

L We observe'that a number of the strategies described in the draft NUREG/CR report either overlap or are very similar to the content of the emergency t

operating procedures that are either being developed or are already in place. in many plants.

We believe that labelling these procedures as accident management strategies where others label them as emergency operating procedures is likely to lead to confusion on the part of both the NRC staff.and the industry.

Sincerely, Forrest J. Remick a hman 8911300261 891120 PDR ACRS g0 R-1376 PDC 4

+*,

s.-.-,,-e-..--.e..

.-**n---

--m.

.,---.-.--.--m.n--..--.s

,w e.-

--w

.s q '

7

. The Honorable Kenneth M. Carr November 20, 1989 References l.

U.S. Nuclear Regulatory Commission, " Accident Management Strategies for Consideration in the Individual Plant Examination Process," Draft Supplement-No. ' 2 to Generic Letter 88-20, dated November 8, 1989 (Predecisional)-

2..

U.S. Nuclear Regulatory Commission, " Assessment of Candidate Accident Management Strategies," Draft NUREG/CR Report (Unnumbered), Prepared by BNL, October 1989 t

i t

L l

l-l.

1 i

1

~

., -,...