Ack Receipt of 800813 Interim Deficiency Rept Re Certain Radiographs of Steam Generator Upper Lateral Support Embedments Not Meeting Density Requirements of Section V of ASME Bp&V Code
ML19332B102
Person / Time
Site: Marble Hill
Issue date: 09/03/1980
From: Fiorelli G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Shields S
PSI ENERGY, INC. A/K/A PUBLIC SERVICE CO. OF INDIANA
References
NUDOCS 8009250483
Download: ML19332B102 (1)


Text

PDR

[gu..

'o UNITED STATES 8'

~,

NUCLEAR REGULATORY COMMISSION I

a REGION lil e

799 ROOSEVELT ROAD e

%g *.sv,e#

GLEN ULLYN, ILLINOIS 60137

..+

Docket No. 50-546 Docket No. 50-547 Public Service of Indiana ATTN:

Mr. S. W. Shields Senior Vice President 4

Nuclear Division 1030 East Main Street Plainfield, IN 46168 Gentlemen:

Thank you for your interim report, dated August 13, 1980, pursuant to 10 CFR 50.55(e) regarding certain radiographs of the steam generator upper lateral support embedments that did not meet the density requirements of Section V of the ASME BP&V Code. We will review your final report on this matter upon receipt.

Your cooperation with us is appreciated.

Sincerely, A"

Mak G. Fiorelli, Chief Reactor Construction and Engineering Support Branch cc:

Mr. G. N. Brown, Project Director Director, RCI/IE Directer, AEOD Chief, OEB/MPA IE Files cc w/Itr dtd 8/13/80:

C. Kammerer, CA H. Thornburg, IE Central Files PDR Local PDR NSIC TIC LeBoeuf, Lamb, Leiby & MacRae Mr. Dave Martin, Office of Attorney General Mr. John R. Galloway, Staff Director, Environment, Energy and Natural Resources Subcommittee 8000250488

h d 13 0 C 4 I C f>

-wy

.e

/

.7

,!OI PUBLIC SERVICE

' INDIANA,

S. W. Shields

~

Senior Vice President -

Nuclear Division August 13,' 1980~

Mr. James G. Keppler, Director Docket Nos.: STN 50-546 U. S. Nuclear Regulatory Commission STN 50-547 Region III Construction Permit Nos.:

799 Roosevelt Road CPPR - 170 Glen Ellyn, Illinois 60137 CPPR - 171 Marble Hill Nuclear Gene 7.ating Station - Units 1 and 2

Dear Mr. Keppler:

On July 17, 1980, Mr. T. D. Geib of Public Service Company of Indiana, Inc., (PSI) notified your office of a potentially reportable item as required by 10 CFR 50.S5(e). The support steel supplier for the Nucicar Steam Supply System, Lakeside Bridge and Steel Company, notified PSI that certain radiographs of the steam generator upper lateral support embedments did not meet the den,sity requirements of Section V of the ASME BP&V Code. As a result, acceptable radiographs of these embedments do not exist at this time and their quality is indeterminate.

PSI is in the process of having the embedments reradiographed in j

accordance with the requirements of Section V of the ASME Code. When thcsc radiographs are completed they will be reviewed to determine the quality of the embedments in question. This letter is intended to fulfill the requirements of an interim report as defined in 10 CFR 50.55(e).

A final report will be submitted on_or before October 20, 1980.

If you have any questions on this report, please feel free to contact me.

l l

Sincerel,

1 1

S. W. Shields TDG/cg cc: Director of Inspection and Enforcement U. S. Nuclear Regulatory Commission AUG 181980 Washington, D. C.

20555 E. R. Schweibinz, P. E.