ML19330C722
| ML19330C722 | |
| Person / Time | |
|---|---|
| Site: | Mcguire |
| Issue date: | 08/04/1980 |
| From: | Parker W DUKE POWER CO. |
| To: | |
| References | |
| SD-370-80-07, SD-370-80-7, NUDOCS 8008110387 | |
| Download: ML19330C722 (2) | |
Text
...
O U K E Powe n Co>m.u:Y Powna Drawixo 400 SocT:s Car cucir STunnT. Cir.wr.oTTE. N C. 2na.u
.u m a m en.a.
August 4, 1980 a.cs =r,a r.c..we 5.c.
24 c
,* La e 4.ihC 'ose 3 3 + 40 9 3 Mr. James P. O'Reilly, Director U. S. Nuclear Regulatory Cor=ission Region II 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303 dIHIS DOCUMENT CONTAINS 4
g Re: McGuire Nuclear Station i
Unit 2 Docket No. 50-370
Dear Mr. O'Reilly:
Pursuant to 10C7R 50.55e please find attached Significant Deficiency Report SD 370/80-07.
ery truly yours,
/,u.m_ G. c O k William 0. Parker, Jr. /
LJB:ses Attachment cc: Director Mr. T. J. Donat Office of Inspection & Enforcement NRC - McGuire Nuclear Station U. S. Nuclear Regulatory Commission Washington, D. C.
20555
?
V So/7 s
//
voosuo3rq s
v DUKE POWER COMPANY MCGUIRE NUCLEAR STATION Report Number: SD 370/80-07 Report Date: August'4,'1980 Facility: McGuire Nuclear Station Unit 2 Identification of Deficiency: Hydrogen Purge System Valve Misapplication Description of Deficiency:
The following deficiency was reported via telecon by W. H. Bradley and J. K. Berry to Mr. John Rausch of the NRC in Atlanta on July 3, 1980. When requisitioning a 1/2" diaphragm valve.from the Construction warehouse, it was-discovered that a Duke Class E (ANSI B31.1) valve had been erroneously assigned to an application requiring a Duke Class B (ASME III, Class) valve.
This Class E valve was not installed.
Analysis of Safety Implication:
Valve 2VE12 is used as a test line drain between containment isolation valves 2VE10A and 2VE11 on the Hydrogen Purge Valve System. Valve 2VE12 is located in the containment annulus area. A potential failure of valve 2VE12 coincident with failure of the inside containment isolation valve 2VEll or piping between isolation valves would provide a leak path for containment environment to-the
. atmosphere.
Corrective Action:
A qualified Duke Class 3 valve has been selected and installed for this application.