.r~y Bechtel Power Corporation Engineers-Constructors 15740 Shady Grove Road Gaithersburg, Maryland 20760 301-258 3000

.u G2, r:r July 22, 19s0 JUL 2 81980 Of fice of Inspection & Enforcement cc:wce[.

-,..,c.,,.

U.S. Nuclear Regulatory Cocsission Region II 101 Marietta Street, N.W.

Suite 3100 Atlanta, Georgia 30303 Attention:

Mr. J. P. O 'Reilly, Director

Dear Mr. O 'Re illy :

Nuclear QA Is Applicable Middle South Energy, Inc.

Grand Gulf Nuclear Station Bechtel Job No. 9645 File:

0260/0512 Final Re port for Bechtel Power Corporation Deficiency Report No. J-80/01 in Compliance with 10CFR 21' V3-80/0268 Our letter of April 24, 1980, forwarded to you, in accordance with 10CFR Part 21, a report of a deficiency at the Grand Gulf Nuclear Station concerning Fase=ount 1151A pressure transmitters.

Our letter also stated that we are investigating -

the matter and would report further within 90 days.

Since that time, your of fice has issued IE Bulletin No. 80-16 which identifies the Rosemount 1151A pressure transmitter problem.

On the Grand Gulf Nuclear Station, further investigation has revealed that there are ten (10) each Rosemount ll51A transsitters on Unit 1 and Unit 2 purchased by the Bechtel Power Corporation which are basic cesponents and =ay produce erroneous outputs when over-ranged or under-ranged in their present applications. Our corrective action will consist of replacing these transmitters with new transmitters

.t.ich do not have this same ambiguous characteristic in the, over-range and under-range condition, and which are qualified in accordance with IEEE 223-1974 and 1EEE 344-1975.

Further details of the follow-up action specific to the Grand Gulf Nuclear Station (GCNS) will be su-=ari:ed in Bechtel Management Correc tive Ac tion Re po rt, GGNS-72 and will be available for your review at tha CGNS construction site,

i For other Eechtel Power Corporation projects with construction per=its, f urther reports will be provided to you in response to IE 3ulletin 30-16.

T g

I 1.

i 1

q g.

s 8008070$O

\\==,/

r i

e Bechtel Power Corporation U.S. Nuclear Regulatory Com::21ssion July 22 1980 Bechtel Job No. 9645 VB-50/02'68 This completes our response to the reporting requirements of 10CFR 21.

Should you require any additional info:mation, please so advise.

Very truly yours,

J.

. Jar P oject Manager JCClub b ec: J.

'P. McGaughy, Jr.

fil L. F. Dale, 2 C. K. McCoy T. H. Cloninger J J. Reaves A. Zaccaria J. M. Kocies B. K. Kanga Dr. D. C. Gibbs R. A. O 'Neil L. E. Ruhland D. M. Lake R. E. Brosm R. L. Scott

/

1 3e e

LJ