ML19330B247

From kanterella
Jump to navigation Jump to search
Safety Evaluation Supporting Amend 61 to License DPR-49
ML19330B247
Person / Time
Site: Duane Arnold 
Issue date: 07/17/1980
From:
Office of Nuclear Reactor Regulation
To:
Shared Package
ML19330B245 List:
References
NUDOCS 8007310226
Download: ML19330B247 (5)


Text

Y 1

fo,,

UNITED STATES 8

NUCLEAR REGULATORY COMMISSION a

h WASHINGTON, D. C. 20555

  • %...../

SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION SUPPORTING AMENDMENT NO. 61 TO LICENSE N0. DPR-49 IOWA ELECTRIC LIGHT AND POWER C0f!PANY CENTRAL IOWA POWER COOPERATIVE CORN BELT POWER COOPERATIVE DOCKET NO. 50-331 DUANE ARN0LD ENERGY CENTER 1.0 Introduction By letter dated June 28, 1980 Iowa Electric Light and Power Company (the licensee) requested reinstatement of Amendment No. C0 to Facility Operating License No. DPR-49 for the Duane Arnold Energy Center (DAEC).

The request would permit the DAEC to operate at up to 50% of rated power with one recirculation loop out of service from June 28, 1980 to July 2,1980.

In April 1980, an equipment malfunction requiring extensive repairs caused one recirculation pump to be taken out of service. The Technical Specifications in effect at that time required a plant shutdown unless the pump was returned to service within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

The licensee submitted an amendment application to permit interim plant operation at reduced power until repairs could be effected.

Amendment No. 60 (transmitted by NRC letter dated May 6,1980, from T. Ippolito to Duane Arnold) modified the DAEC Technical Specifications to permit plant startup and operation with one recirculation loop out of service during the requested period necessary to effect repairs. The power level was limited to 50%

of rated power. Amendment No. CO was applicable only for the period required to effect the necessary repairs.

On June 27, 1980, an equipment malfunction, unrelated to the afore-mentioned, caused one recirculation pump to again be taken out of service. Repairs were necessary which could not be effected within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

The licensee requested the provisions of Amend-ment No. 60 to be reinstated until July 2,1980.

2.0 Evaluation 2.1 Accidents (Other than LOCA) and Transients Affected by One Recirculation Loop out of Service 8007810 $

~

4 2.1.1 Ode Pump Seizure Accident The licensee has qualitatively compared the consequences of a pump Meizure accident during single loop operation with the consequences of a LOCA during full power operation with both loops in service.

Previous analyses have demonstrated that the pump seizure accident is not as severe as a LOCA for two pump operation. The same conclusion can be made for the one pump case by analyzing the two events.

In both events, the recircula-tion driving loop flow is lost instantaneously, in the seizure because of pump stoppage, in the LOCA because of a line severance.

In the seizure event, natural circulation flow continues, water level is maintained, and the core remains submerged; thus a continuous core cooling mechanism is provided. However, for a LOCA complete flow stoppage occurs and the water level decreases, resulting in core uncovery and subsequent fuel rod cladding overheating.

In addition, the reactor pressure does not decrease for a pump seizure event, whereas complete depressurization occurs for the LOCA.

Since the potential effects of a pump seizure accident are bounded by the effects of a LOCA, the licensee has taken the position that specific pump seizure analyses for one loop operation are not necessary.

Although this gives some assurance of acceptability of the Jmp seizure event, the staff notes that the acceptance criteria for pump seizure are more stringent than the criteria for a LOCA.

Standard Review Plan 15.3.3 (Reactor Coolant Pump P.otor Seizure, and Reactor Coolant Pump Shaft Break) requires that for the pump seizure accident, the release of. radioactivity should be a fraction of 10 CFR 100 guide-lines. Only limited amounts of fuel failures are acceptable for pump seizures, whereas significantly more failures are acceptable for LOCA.

The licensee, however, will limit reactor power during single loop operation to 50% of rated power. As indicated on the DAEC power / flow operating map, the natural circulation line intersects the 100% flow control line at 53% power. Thus, with pcwer limited to 50%, reactor power is at a value where no fuel damage will occur even if pump sci-zure should occur.

The staff finds the power limit of 50% to be acceptable on the basis that the power limit will assure no significant fuel damage will result should the pump seizure event occur during one loop operation at DAEC.

2.1.2 Abnormal Transients l

. 2.1.2.1 Idle Loop Startup The idle loop startup transient was analyzed, in the DAEC FSAR, with an initial power of 55%.

The licensee has committed to operate at no greater than 50% power with one loop out of service. Additionally, tho Technical Specifications are being modified to require that, du 'ng single loop operation, the suction valve in the idle loop be shut and electrically disconnected. These measures are being taken to preclude startup of an idle leop.

2.1.2.2 Flow Increase i

The Minimum Critical Power Ratios (MCPRs) in the present Technical Specifications for operation at full power have previously been reviewed and found to be Seceptable. A large inadvertent flow increase could cause the MCPR to decrease be7cw the Safety Limit MCPR for a low initial MCPR at reduced flow conditions.

Therefore, the required MCPR must be increased at reduced core flow by a flow factor, Kr.

The Kf factors are derived assuming both recirculation loops increase speed to the maximum permitted by the scoop tube position set screws. This condition maximizes the power increase and hence the AMCPR for transients initiated from less than rated con-ditions.

When operating on one loop the flow and power increase will be less than with two pumps increasing speed, therefore the Kf factors derived from the two-pump assumption are conservative for one loop operation.

2.1.2.3 Rod Withdrawal Error The rod.dthdrawal error at rated power analysis indicated that the rod block monitor (RBM) will stop rod withdrawal at a critical power ratio (CPR) which is higher than the safety limit. The minimum critical power ratio (MCPR) requirement for one loop operation will be equal to that for two loop operation because the nuclear character-istics are independent of whether core flow is attained by one or two pump operation, if flow asymmetries are not incurred with one-loop operation.

Tests at Quad Cities have shown that flow is uniform across the core for one pump operation with the equalizer valve closed.

The results of these ' tests are considered applicable and acceptable for DAEC.

One-pump operation results in backflow through 8 of the 16 jet pumps while flow is being supplied to the lower plenum from the active jet pumps.

Because of this backflow through the inactive jet pumps the present rod-block equation and APRM settings must be modified.

The licensee has modified the two-pump rod block equation and APRM settings diat exist in the Technical Specification, for one-pump operation and the staff has found them acceptable.

l e

. The staff finas that one loop transients and accidents other than LOCA, which is discussed below, are bounded by the two loop operation analysis and are therefore acceptable.

2.2 Loss of Coolant Accident (LOCA)

The licensee has contracted General Electric Co. (GE) to perform single loop operation analysis for DAEC LOCA.

The licensee states that preliminary evaluation of these calculations (that are per-formed according to the procedure outlined in NED0-20566-2, Rev. 1) indicates that a multiplier of 0.86 should be applied to the MAPLHGR limits for single loop operation of the DAEC.

The licensee asserts further that GE has performed a large number of single loop analyses for similar plants; and, in no case has a multiplier of less than 0.70 been required.

Additionally, because DAEC does not have the LPCI modification and because the limiting LOCA break is a suction line break, the single loop MAPLHGR multiplier is expected to be significantly larger than for most other BWRs.

However, the licensee has proposed that, until the GE calculations can be verified, a multiplier of 0.E5 be utilized.

The staff's evaluation finds that value of MAPLHGR reduction factor to be conservative and, therefore, acceptable.

3.0 Summary For the reasons previously discussed, the staff finds acceptable the proposed single loop operation until July 2,1980.

Power is limited to no greater than 50% of rated power.

4.0 Environmental Considerations We have determined that this amendment does not authorize a change in effluent types or total amounts nor an increase in power level and will not result in any significant environmental impact. Having made this determination, we have further concluded that the amendment involves an action which is insignificant from the standpoint of environmental impact and pursuant to 10 CFR Section 51.5(d)(4) that an environmental impact statement, negative declaration, or environ-mental impact appraisal need not be prepared in connection with the issuance of this amendment.

. 5.0 Conclusion We have concluded, based on the considerations discussed above, that:

(1) because the amendment does not involve a significant increase in the probability or consequences of accidents previously considered and does not involve a significant decrease in a safety margin, the amendnent does not involve a significant hazards consideration, (2) there is reasonable assurance that the health and safety of the public will not be endangered by operation in the proposed manner, and (3) such activities will be conducted in compliance with the Commission's regulations and the issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public.

Dated:

e-y-

y-n m

n e--m,-

~

r