05000366/LER-1980-098-03, /03L-0:on 800626,w/reactor at 99% Steady State Power,Hpci Pump Failed Operability.Caused by HPCI Pump Suction Pressure Transmitter 2E41-N019 Drifting Out of Tolerance Causing 2E41-R606 to Indicate Incorrectly

From kanterella
(Redirected from ML19330A519)
Jump to navigation Jump to search
/03L-0:on 800626,w/reactor at 99% Steady State Power,Hpci Pump Failed Operability.Caused by HPCI Pump Suction Pressure Transmitter 2E41-N019 Drifting Out of Tolerance Causing 2E41-R606 to Indicate Incorrectly
ML19330A519
Person / Time
Site: Hatch 
Issue date: 07/14/1980
From: Nix R
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19330A518 List:
References
LER-80-098-03L, LER-80-98-3L, NUDOCS 8007280512
Download: ML19330A519 (2)


LER-1980-098, /03L-0:on 800626,w/reactor at 99% Steady State Power,Hpci Pump Failed Operability.Caused by HPCI Pump Suction Pressure Transmitter 2E41-N019 Drifting Out of Tolerance Causing 2E41-R606 to Indicate Incorrectly
Event date:
Report date:
3661980098R03 - NRC Website

text

' ' ' " ' ' ' " ' " '

WRC FORM 366 inn LICENSEE EVENT REPORT P's CON 7ROL DLOCK: l l

l l

l l lQ (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) 1 6

0111IclAlElIlul21@l0101 1010101010 l l o l o l@l 4 li 11 1111 l@l I

l@

8 9 LICENSEE CODE 14 lb LICENSL NUMBLR 25 2G LICLfwSE TYPE JO b / CA T 68 CON'T Ol1l sob "C l L l@l 0 l 5 l 0 l 0 l 0 l 3 l 6 l 6 l@l 0 l 6 l 2 l 6 l 8 l 0 l@! O l 7 l 1 l 4 ! 8 I

8 60 61 DOCKET NUMBER 68 09 LVENT DATE 14 75 REPORT DAT E 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h lo l2l l While the reactor was at 99% steady state power, operations declared g

IIPCI pump f ailed operablility per IINP-2-330 3, llPCI Pump Operability, l

[o lal l due to low suction pressure indication. There was no affect upon the l

g o l4 ; l environs. This is a non-repetitive event.

RCIC, ADS, LPCI mode of g

l O 15 ] l l 016 l l RIIR and CSS were operable.

l l

10171l l

lolH ] l 80 SYSTEM

CAUSE

CAUSE COMP.

VALVE CODE COuE SUBCODE COMPONENT CODE SUBCODE SUBCODE IIlBjg {E]g lElg lIlNlSlTlRlUlQ g l Zlg O 9 7

8 9

10 11 52 13 18 19 20 SEQUENTIAL

' OCCURRENCE REFORT riEVISION Lgg.RO EVENT YEAR REPORT NO.

CODE TYPE NO.

@ mgg 18101 1-1 1019181, [gj l0 l3 l l LI l-l l0 l a

_ 21 22 23 24 26 21 28 23 30 31 32 TK f A T O L NT L

H HOURS SB IT FO b 3.

S PPLIE MAN FACTUFER [E_)hdh l35Z l h (36Z_lhl 0 l 0 l 0 l 0 l W@

lY lh l Nl@

l G l 0l 8l 0l@

33 34 34 40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS 11 lO ] l IIPCI Pump Suction Pressure Indicator, 2E41-R606, was indicating low l

1 i l

due tcr llPCI Pump Suction Pressure Transmitter, 2E41-N019, having drifted

]

l,g7l l out of tolerances causing 2E41-R606 to indicate incorrectly. The trans-j liIal l mitter was recalibrated and returned to service.

l l

i 4 l

80 7

8 9 ST S

% POWER OTHER STATUS ISCO RY DISCOVERY DESCRIPTION NA l

[gl Normal Surveillance l

y @ l0l9l9j@l i 5 t TIVITY CO TENT RELE ASED Or RELEASE AMOUNT OF ACTIVITY LOCATION OF REL EASE NA l

l NA l

d h Whl I G 7

8 9 10 11 44 45 80 PERSONNEL EXPOSOHES l 0l 0l 0lhl TYPE @l DESCRIPTION NUMBER Zl NA l

1 7 PERSONNELINJU IES NUVBER DESCRIP TION NA l

l0lOlOl@l i a 80 7

8 9 11 12 LOSS OF OR DAMAGE TO FACILtTV Q 1YPE

DESCRIPTION

v

"^

l LzJ@l i o 80 7.

J 9 10

~

155UEll@ DESCRIPTION L N_

l NA l

lllllllllllll{

2 O 68 6'

So 5

,800728p(19-NAME OF PREPARER PHONE:

_ {

912-367-7781

NARRATIVE

REPORT Georgia Power Company Plant E.

I.

Hatch Baxley, Georgia 31513 Reportable Occurrence Report No.50-366/1980-098.

While operations were performing HPCI Pump Operability Procedure, HNP-2-3303,-

HPCI Pump Suction Pressure Indication, 2E41-R606, was discovered to be in-dicating low and operations shut down the HPCI system. This occurred while the reactor was at 99% steady state in power.

The operation of the plant was not affected and there was no affect on the environs.

This is a non-repetitive event.

RCIC, ADS, LPCI mode of RHR and CSS were operable.

The cause of the event has been attributed to HPCI Pump Suction Pressure Transmitter, 2E41-N019, having drifted out of tolerance causing 2E41-R606 to indicate incorrectly.

Upon discovery, the transmitter was recalibrated and returned to service.

This is not a generic problem.

j i

a 1