ML19329E481

From kanterella
Jump to navigation Jump to search
Forwards AEC Rept, Technical Rept on Densification of LWR Fuels. Requests Analyses & Data to Determine Consequences of Transients & Accidents.W/O Encl
ML19329E481
Person / Time
Site: Midland
Issue date: 11/20/1972
From: Anthony Giambusso
US ATOMIC ENERGY COMMISSION (AEC)
To: Youngdahl R
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
References
NUDOCS 8006160284
Download: ML19329E481 (2)


Text

.

gb s s co~4 UNITED STATES g

I' ATOMIC ENERGY COMMISSION

~~

\\

J*

wAsa:NoTou, o.c. zos4s

  • Wp,

%ne Docket Nos.

50-329

November 20, 1972 and,50-330 THIS DOCljMENT CONTAINS Consummers Power Company ATTN: Russell Youngdahl POOR QUALITY PAGES Senior Vice President 212 West Michigan Avenue Jackson, Michigan 49201 RE: Midland Plant, Units 1 and 2 Gentlemen:

The Commission's Regulatory Staff has completed a review of fuel densification and its effect on reactor operation including transients and postulated loss-of-coolant accidents. The Staff's investigations and conclusions are reported in " Technical Report on Densification of Light Water Reactor Fuels" dated November 14, 1972, a copy of which is enclosed for your information and guidance.

This report concludes that d.insification of fuel may occur and that the resulting formation of fuel colu=n gaps should be anticipated in all light water reactor fuels. The report also provides the essential elements to be included in calculational models used to account for the effects of fuel densi-fication.

The Regulatory Staff believes that the fuel for the subject facility (s) is susceptible to densification.

Therefore, we request that you provide the necessary analyses and other relevant data for determining the conse-quences of densification and the ef fects on normal operation, anticipated transients, and accidents, including the postulated loss-of-coolant accident, using the guidance provided in the enclosed report.

If the analyses indicate that changes in design or operating conditions are necessary to maintain required margins, you should submit proposed changes and operating limitations with the analyses.

n. ~ n b%

fl lc.:.

S ' "

C n ' J '"" " *

'k

._, c_

~

g f

4 tcy y

. CA b.

% ' W '- lW' W

[

800616 J

.r

-s

/

Consu==ers Power Company In order'that the Regulatory Staff can conduct an expeditious and orderly review of these catters, we request that you submit the analyses and additional information within 45 days frem the date of this letter.

It is requested that this infor=ation be provided with one signed original and thirty-nine additional copies.

If your submittal is for more than one unit, a total of sixty copies is needed.

S,incerely,

A.dw &

A. Giacbusso, Deputy Director for Reactor Projects Directorate of Licensing

Enclosure:

~

Technical Report on Densification (November 14, 1972) cc: Grace Down Me=orial Library 1710 W. St. Andrews Road Midland, Michigan 48640 So e e

e

.