ML19329E447

From kanterella
Jump to navigation Jump to search
Forwards Interim Deficiency Rept Re Component Cooling Water Pump Casing Design.Next Rept Will Be Sent 770415
ML19329E447
Person / Time
Site: Midland
Issue date: 12/10/1976
From: Howell S
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: Volgenau E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
Shared Package
ML19329E446 List:
References
HOWE-178-76, NUDOCS 8006160251
Download: ML19329E447 (1)


Text

-

. w) ^

./ %

Consumers g

power f\\

Stephen H. Howell

.$ W,,- /

Vice President

=

Generet Offices: 1945 West PerneH Road, Jackson, MicNgen 49201

  • Area Code 517 788 0453 December 10, 1976 Howo-178-76 Dr. Ernest Vogenau, Dirce'mr Office of Inapoetion and Enforecnent U3 I!ueler.r EcMatory Con =ission Washington, LO 20955 MIDLUID PIWif C0!!PO?Z.T COGLII;G WlODI PJMP C/.GII:G LD'ICII:I:CY DoCICI I.ts 50-329 M m 90-330 The report n.tt.ched to this letter describes c. deficiency in the do. tic 1 of co.q>onant cor>1 ire; ve.tcr pt'np casini;3 for the Midland Pro,1cet. This letter is an interin report sicuitted per 10 CMI %.95(c) cud another report vill da cent on April 15, 1977 l

M l

CC: Director, Office of th:rt; enent Information and Pro gem Control 13C, Utchington, DC i

yJGKoppler (2),130, Rc;; ion III l

l l

i 8006160 $ E DEC 131976

_