ML19329D647

From kanterella
Jump to navigation Jump to search
Forwards Gilbert & Associates Analytical Model, Borated Water Storage Tank Drawdown Transient Analysis, Revision 1. W/O Encl
ML19329D647
Person / Time
Site: Crystal River 
Issue date: 03/16/1976
From: Rodgers J
FLORIDA POWER CORP.
To: Darrin Butler
Office of Nuclear Reactor Regulation
References
NUDOCS 8003160271
Download: ML19329D647 (3)


Text

I NRC peru 105 U.S. NUCLE AR REGULATORY CO' *tSSION DOCKET NUMBER

.2 7.

So-3oL NRC DISTRIBUTION FOR PART 50 DOCKET MATERIAL TO:

FROM: FLORIDi POWER CORP DATE OF DOCUMENT DR D \\ St'TLER ST PETERSBURG. FLA b~ Ib'%

DATE RECEIVED

.I T RODGERS g_q,gg LETTER CNOTORIZED PROP INPUT FORM NUMBER OF COPIES RECEIVED C ORIGIN AL kUNC L ASSIFIE D MCc,PY

$o DESCRIPTION EN CLOSU R E LTH FUR!' 1MFO ON T TE DR 4 lD0'.:N TEST CONDUCTED BORiTED 1;ATER STORAGE T.,NK DRdDO'.!t:

PY GTLHERT AS W IATES.

TRaNS THi? FOLLO 1-TRANSIENT AN ALYSIS FOR CRYST '.L RTdR T' NIT C ING.

DISTRIBUTION PER MR I.

ENGLE C,,y,gsTg,3w q,R % 1 F M NAME-

{

g 1 COPY FOR MR MAZETIS o

~

SAFETY FOR ACTION /INFORMATION ENVIRO S- / 2-76 R k(<

1 ASSIGNED AD :

DEN ovn G,.

ASSIGNED AD :

)(

BRANCH CHII:P :

3 u"I-G R BRANCH CHIEF :

)(

PROJECT MANAGER:

L. Enc,LE PROJECT MANAGER :

LIC. ASSI. :

LIC. ASST. :

~

~

INTERNAL DISTRIBUTION Y fREG FILP J SYSTEMS SAFETY PT. ANT SYSTEM 9 FWTRO TFr*M

/ 'rinu ruR HETNEMAN TFnF9cn ERNST I&E scunnFnER X

BENAROYA BALLARD OELD IAINAS SPANGLER GOSSICK & STAFF ENGINEERING X

IPPOLITQ/SZU KIE WIC2 SITE TECH MIPC MAccAny CASE KNIGHT OPERATING REACTORS GAMMILL HANAUER SIINEIL STELLO STEPP HARLESS PAWLICKI HULMAN OPERATING TECH PROJECT MANAGEMENT REACTOR SAFETY EISENHUT SITE ANALYSIS BOYD ROSS SHA0 VOLLMER P. COLLINS X

NOVAK (D %

BAER BUNCH HOUSTON ROSZTOCiY SCHWENCER J. COLLINS PETERSON CHECK GRIMES KREGER MELTZ F

HELTEMES AT & I SITE SAFETY & ENVIRC SKOVHOLT SALTZMAN ANALYSIS RUTBERG DENTON & MULLET ?ASE'bh 6r

~

EXTERN AL DISTRIBUTION CONTROL NUMBER X

LPDR:CtW1TAL C3ve,e,yt.

NATL LAB BROOKHAVEN NATL LAE TIC REG. V-IF ULRILSON(ORNL)

IISIC LA PDR ASLB CONSULTiNTS ACRS HOLDING /SENT 8 0 031,60 M. f NRC rORu as im.7e'

.?:

o

. n 36 R:

. 30%

WKf): p.OE99p*

YQ).:% Ob7.2 saans Florida Pw 4m c o.o,o...er March,q6:,4976'..

.o~

55-t:

x

' :.,. ' ' IE;g Dr. D. A. Butler, Chief

()

(,'.

Light Water Reactors Branch #4

'e'/i-Director of Nuclear Reactor Regulation u.S. Nuclear Regulatory Commission

' O ~~

Washington, D. C. 20555 In Re:

Florida Power Corporation Crystal River Unit #3 Docket No. 50-302

Dear Dr. Butler:

We enclose 20 copies of Gilbert Associates Analytical Model -

Borated Water Storage Tank Drawdown Transient Analysis, Revision 1.

This analysis has been applied to Crystal River Unit #3 system design and verified during the recently run Borated Water Storage Tank Drawdown Test.

The BWST drawdown test is not a design basis test.

It should be noted that the physical (actual) dwdown test was con-ducted with demineralized water and tc.t actual LOCA conditions did not exist.

Therefore, the function of the physical draw-down test was solely to verify an analytical model.

This model was then used to evaluate the design basis operation of the tank drawdown.

Replacement of stop check valves BSV-9, 10, 67 and 68 with swing check valves does not invalidate the analytical model because of the predictability of valve pro-perties by industry standardo.

A drawdown retest would again give indication of water hydraulics only and would not demonstrate the adequacy of the system relative to design conditions.

Regardless of physical drawdown results utilizing water, the requirement to validate the FSAR can be accomplish 2d only with the pre-viously verified analytical model.

_b9' General Office 3201 inirty.fourin street soutn. P O Box 14042. st Petersburg Florca 33733 813-666-5151

Dr. D. - A. Butler March 16, 1976 We'would appreciate your acceptance of this Analysis and the previously run drawdown test as adequate to demonstrate system performance.

Very truly yours, J. T. Rodgers Asst. Vice President

~~

JTR/iw Attachments.

S e

4 i

e 9

.... - - _.