ML19329A546
| ML19329A546 | |
| Person / Time | |
|---|---|
| Site: | Oconee |
| Issue date: | 03/28/1972 |
| From: | Peltier I US ATOMIC ENERGY COMMISSION (AEC) |
| To: | Morris P US ATOMIC ENERGY COMMISSION (AEC) |
| References | |
| NUDOCS 8001070492 | |
| Download: ML19329A546 (2) | |
Text
sp j
l
[
h~bb
[%h,.
UNITED CTATES ATOMIC ENERGY COMMISSION W ASHINGTON. D.C. 20545
%,g..Q c '
._"E 1 3 62 sr.,n e P. A. Morris, Director, Division of Reactor Licensing THRU:
A. Schwencer, Chief, Pressurized Water Reactors Branch No. 4, DRL MEETING WITH DUKE POWER COMPANY AND BABC0CK AND WILCOX CONCERNING OCONEE NUCLEAR POWER STATION UNIT NO. 1 DOCKET No. 50-269 Time and Date:
9:30 a.m.
April 6, 1972 Location:
Barberton, Ohio
Purpose:
B&W presentation on how it plans to repair and if necessary modify the A steam generator from Oconee Unit 1, which was damaged during recent hot functional tests.
(Agenda attached)
Participants:
Duke Power Company DRL (A. Sc'hwencer, I. Peltier)
DRS (D. Lange)
CO (Region II & Headquarters)
RDT 4 eb.TJ' 0
3 I. A. P leier, Project Leader Pressurized Water Reactors Branch No. 4 Division of Reactor Licensing DISTRIBUTION SHHanauer, DR MShaw, RDT FSchroeder, DRL JHunter, RDT DRL Assistant Directors DLange, DRS EGCase, DRS DRL Reading RRMaccary, DRS Docket DFKnuth, DRS PWR-4 Reading RBMinogue, DRS LRogers, DREP PWR Branch Chiefs RFFraley, ACRS C0 (4)
RWKlecker, DRL FWKaras, DRL iPeltier, DRL 4
w a
o.
..t}
AGENDA Babcock and Wilcox Introductory Comment
' I.
Steam Generator A 1.
Development of Welding Techniques 2.
Development of Machining Technology 3.
Metallurgical Condition of Metal 4.
Processing and Procedures 5.
Records, Quality Assurance and Quality Control 6.-
Test for vessel Integrity i
II.
Steam Generator B Repair b
o 9
O 4