Notice of Violation from Insp on 771011-19
ML19329A479
Person / Time
Site: Oconee  
Issue date: 11/28/1977
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML19329A471 List:
References
50-269-77-24, 50-270-77-24, 50-287-77-24, NUDOCS 8001031049
Download: ML19329A479 (1)


Text

,

.t

.. ~

- - -. ~ ~ -

1 3

)

)

g)

APPENDIX A NOTICE OF VIOLATION Duke Power Company License Nos..DPR-38 DPR-47 DPR-55 Based on the results af the NRC inspection on October 11-19, 1977, it appears that certain of ycur activities were not conducted in full t

compliance with NRC facility license Nos. DPR-38, DPR-47 and DPR-55 as l

indicated below.

A.

Technical Specification 6.41 states that the station shall be i

operated and maintained in accordance with approved procedures and i

that written procedures with appropriate check-off lists and instructions shall be provided, in part, for Emergency Procedures involving potential or actual release of radioactivity, and Radiation Control procedures. Health Physics procedure, HP/0/B/1009/04,

" Scott Air Paks II and III, Self Contained Breathing Apparatus,"

requires that all Scott Air Paks be thoroughly inspected once per month and the inspection information be placed on a tag on the

< w case.

.s Contrary to the above, on October 12, 1977, an inspector observed the inspection tags on two Scott Air Paks in Unit 1 and 2 control room which indicated they had not been Inspected during June, August, September and December of 1976 and February, March and August of 1977.

Two Scott Air Paks in Unit 3 control room and one Scott Air Pak in the administrative building first aid room had inspection tags which indicated similar missing inspection dates.

This is an infraction.

B.

Technical Specification Table 4.1-1 requires a monthly battery check and annual calibration of emergency survey instruments.

Contrary to the above on October 12, 1977, an inspector observed that the emergency survey instruments HP 69-2 in Unit 3 control room and HP 69-1 in Units 1 and 2 control room had apparently last received a conthly battery check on March 24, 1977 and May 4, 1977, respectively.

This is a deficiency.

\\ -

.s' 0001081L:)ficy