s x
- 'V MISAPPLICATION OF CRANE COMPANY 10 INCH 300 POUND CAST ALLOY STEEL VALVE - CATALOG NUMBER 151 1/2 LU.
l A recent unusual event report submitted by a licensee of a PWR plant, supplied by B&W, indicated the failure of valve internals in a valve in the low pressure injection system. This has been the third failure of this nature in a two year period, c
k~
A.
Description of Circumstances f
The low pressure injection system was being operated in the decay
. heat removal mode when it was noted that flow could not be f
throttled below 4003 gpm. The system had been in operation for an extended period at flows less than 3000 gpm.
Visual inspection I
of the valve revealed that the guide pin on the base of the valve l
disc had broken off. Previous failures had been with the disc i
guide bar and the disc guide pin.
i 1
The valve manufacturer advised the licensee that this valve was not intended for regulating service. Operation in a regulating mode causes vibration and/or cavitation and results in failure.
I
.j B.
Action Requested i
Please supply this office, in writing within 30 days af ter receipt C
of this bulletin, the following requested information:
- 1. Are similar valves used in any safeguard system in your facility?
- 2. Are they used as flow regulating or throttle valves?
- 3. If the valves-are used for flow regulation or as throttle valves, i
8001020 g
=-.-
T c
-~-
j.
-J 3, -.
2 '- -
y
-: et.
4 Jl, what action have you taken_or-do you plan to take to minimize i
i
^
the potential for failure of valve internals?
r
- 4. 'If this bulletin does not apply to your facility, a. negative
~
{
report is requested.