D DA/RYLAND
/
h COOPERAT/VE eo BOX 817 2615 E AST AV SOUTH = LA CROSSE ulSCONSIN M601 ace 7ns :ono July 28, 1980 In reply, please refer to LAC-7058 DOCKET NO. 50-409 Director of Nuclear Reactor Regulation ATTN:
Mr. Dennis M. Crutchfield, Chief Operating Reactors Branch #5 Division of Operating Reactors U.
S. Nuclear Regulatory Commission Washington, D.
C.
20555
SUBJECT:
DAIRYLAND POWER COOPERATIVE LA CROSSE BOILING WATER REACTOR (LACBWR)
PROVISIONAL OPERATING LICENSE NO. DPR-45 ADDITIONAL INFORMATION REQUIRED FOR NRC STAFF GENERIC REPORT ON BOILING WATER REACTORS
References:
(1)
DPC Letter, Linder to Ziemann, LAC-6486, dated September 7, 1979.
(2)
NUREG-0578, "TMI-2 Lessons Learned Task Force Status Report and Short-Term Recom-mendations", forwarded by NRC Letter, dated August 6, 1979.
(3)
NRC Letter, Ziemann to Linder, dated July 31, 1979, 1
(4)
NRC Letter, Ziemann to Linder, dated July 17, 1979.
Gentlemen: of this letter includes revised pages 1, 2,
and 6 of of Reference 1.
The Safety / Relief Valves section of page 6 has been updated to include direct position indication of the valves in the Control Room.
This plant modification was completed in April 1980.
The High Pressure Core Spray section of page 2 has been corrected to include initiation by a 5 PSIG Containment Building pressure signal which serves as the diverse parameter to actuate High Pressure Core Spray.
Pages 1 and 6 have been revised to show that valve position indi-cations in the Control Room for various systems are direct, as described in Section 2.1.3a in Appendix A of Reference 2.
Position indication for each of the specified valves is provided by limit switches which give reliable position indication of the valve stem.
1-THIS DOCUMENT CONTAINS POOR QUALITY PAGES
.=.
4 Mr. Dennis M. Crutchfield, Chief
-LAC-7058 Operating Reactors Branch #5 July 28, 1980 s
If there are any-questions regarding this submittal, please contact us.
Very truly yours, DAIRYLAND POWER COOPERATIVE LL
'L Frank Linder, General Manager FL:FD:af Enclosure cc:
J.
Keppler, Reg. Dir., NRC-DRO III j.
.. _.