Suppls Response to IE Bulletin 80-12 Decay Heat Removal Sys Operability. Subsequent Review Determined That Containment Isolation Must Be Blocked Independently.Action Has No Effect Upon Operation of RHR Sys
ML19327A160
Person / Time
Site: Maine Yankee
Issue date: 07/09/1980
From: Johnson W
Maine Yankee
To: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
IEB-80-12, WMY-80-107, NUDOCS 8008010211
Download: ML19327A160 (1)


Text

- _ _ _

MAIRE ",21UARHEE AmmiGF0WERCCMF.MU

  • rugu,,,, g o,o,,,,,
$1. NF '

ENGINEERING OFFICE WESTBORO, MASSACHUSETT3 01581 6 " -366-90 "

July 9, 1980 B.4.1.1 United States Nuclear Regulatory Commission WMY 80-107 Of fice of Inspection and Enforcement Region I 631 Park Avenue King of Prussia, Pennsylvania 19406 Attention:

Mr. Boyce H. Grier

References:

(a) License No. DPR-36 (Docket No. 50-309)

(b) MYAPC Letter to USNRC (WMY 80-90), dated June 9, 1980 (c)

IE Bulletin No. 80-12 " Decay Heat Removal System Operability dated May 9, 1980

Subject:

Decay Heat Removal System Operability

Dear Sir:

Our letter, Reference (b), in response to Reference (c), indicated that blocking the Safety Injection Activation System would also automatically block containment isolation.

Subsequent review has determined that this is not the case. Containment isolation must be blocked independently; however, this action has no af fect upon the operation of the Residual Heat Removal (RHR)

System.

Therefore, this information does not alter the conclusions derived or actions described in Reference (b), to ensure the operability of the RHR system.

We apologize for any confusion which might have arisen, and trust that this information is satisfactory. Hcvever, should you require any further information, please feel free to cec act us.

Very truly yours, MAINE YANKEE ATOMIC POWER COMPANY Lo W. P. Johnson Vice President COMMONWEALTH OF MASSACHUSETTS)

)ss COUNTY OF WORCESTER

)

Then personally appeared before me, W. P. Johnson, who, being duly sworn, did state that he is a Vice President of Maine Yankee Atomic Power Company, that he is duly authorized to execute and file the foregoing request in the name and on the behalf of Maine Yankee Atomic Power Company, and that the statements therein are true to the best of his knowledge and belief.

Rob'ert H. Groce '

Notary Public L

$008010 My Commission Expires September 14, 1984