Gentiemen:
\\
Thank you for your final report dated. May 27, 1977, pursuant to 3
10 CFR 50.55(e) regarding component cooling water pump casings.
i We have no further questions,regarding this matter at,this time.
t Your cooperation with us is l'ppreciat_ed.
, Q'
~...
Sincerely,
\\
R. P. Heishnan, Chief
.i.\\
Reactor Construction and Engineering Support Branch ec w/1tr dtd 5/27/77:
s Central Files Reproduction Unit NRC 20b
, PDR
,g, Local PDR NS1C tic Ronald Callen, Michigan Pisbl,ic Service Comission Dr. Wayne E. North Myron M. Cherry, Chicago THIS DOCUMENT CONTAINS POOR QUAUTY PAGES 8006180
/
p p GD
^
RIII RIII or,,e s,
VandelIIs
-hayedO lleir i. n 6/2/77 oave
- NRC PORM 313 (p.76) NRCM 0240 W u. s. eaves==usur,nanrine o,,,can tore -ese.es4 J.... }
n,
.,-..-~~--..n n ( ~ p
~~....,.... s -...
~
(.
()
E
. f :::N
/
p8"
CEU!illBIS i:
\\
- ';;.T
,' [ij Stephen H. Howell Vice l>ni. lent General Of fices: 1945 West Parnait Road, Jackson, Michigan 49201
- Area Code 617 788 0453
.May 27, 1977 J owe-89-77 s
,i I
Office of Inspection and Enforcement
,Att: Mr 'J G Keppler, Regional Director Region III US Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137 MIDIAND NUCLEAR FIANT - COMPONENT COOLING WATER CASINGS FINAL REIORT - DOCKET NOS 50-329 AID 50-330 On April 5,1977, per 10 CFR 50.55(e) we provided an interim report on the design of coc:ponent cooling water pump casings. This report is a final repcrt in that the corrective action and the safety implications of the correction have been determined.
It has been decided to cancel th'e procurement of these pumps from BfhW Canada Ltd.
A new purchase order will be plD.ced with another supplier.
There are no unresolved r afety implications associated with this corrective action because the new purchase order specifies component cooling water pumps which are in compliance with the Midland ISAR commitments.
l 4whG*
CC: Dr Ernst Volgenau (15)