Requests Stress Analyses of Containment Concrete Per Design Mod in Supp 15 to Application.Placement of Concrete for Containment Walls May Commence
ML19326B949
Person / Time
Site: Arkansas Nuclear 
Issue date: 01/26/1970
From: Morris P
US ATOMIC ENERGY COMMISSION (AEC)
To: Phillips J
ARKANSAS POWER & LIGHT CO.
References
NUDOCS 8004180659
Download: ML19326B949 (2)


Text

s

&b$ 50 ~ 3 ' 3 UNITED STATES g

, g j, ATOMIC ENERGY COMMISSION j.j g

WASHINGTON. D.C. 20543

'Mr January 26, 1970 Docket No. 50-313 Arkansas Power and Light Company Pine Bluff, Arkansas 71601 Attention:

Mr. J. D. Phillips Vice President and Chief Engineer Gentlemec:

We have reviewed Supplement No.15 to your application for licensing of the Arkansas Nuclear.cne facility. That supplement describes a design modific.ation for.the buttress reinforcement of the containment struc-ture. On the basis of the stress values and safety margins indicated, we find no technical objection to commencement of concrete placement for the containment walls.. However, in order for us to complete our review of this modification, we will require additional information.

In particular, we believe that..to determine the bursting force, the selected percentage of the applied load must be justified and that the most conservative condition' of cracking should be used.

We request that you provide (1) an analysis in support of a selected percentage of applied prestress load to be assumed as the bursting force, assuming cracked concrete and (2) an analysis to check whether the anchorage can be maintained in static equilibrium, assuming the same conservative crack pattern used in (1), and a determination of corresponding stresses.

The analysis requested for item (2) should also account for the three dimensional stress field and the effects of the thermal gradients.

In addition, it should consider three locations in the buttress: at bottom mat, approximately half way up the buttesss, and adjacent to the ring girder at the dome. Tests, in lieu of such an analysis, would also be acceptable to us.

This information should be presented to.the staff as soon as possible, prior to the third pour.

i l

,e F

800418063 i

/

_.,.g.,,.

~-

.~

9..

Mr. J. D. Phillips 2

January 26, 1970 Please contact us if you desire any discussion or clarification of.

the material requested.

\\

Sincerely yours,

\\

\\

Original Signed py

.d.

Retgf, Moms f N

Peter A.. Morris, Director Division of Reactor Licensing cc:

Mr. Harlan T. Holmes Nuclear Project Manager Arkansas Power & Light Company Sixth & Pine Streets Pine Bluff, Arkansas 71601 1

Mr. Horace Jewell House, Holmes & Jewell 1550 Tower Building Little Rock, Arkansas 72201

?