ML19326B347

From kanterella
Jump to navigation Jump to search
Advises of Loose Lower Tube of Control Rod Grapple.Caused by Improperly Torqued Cap Screws & Unstaked Nuts.Nuts Staked, Holes Drilled,Bolts Inserted & Properly Torqued.Problem Appears Nongeneric
ML19326B347
Person / Time
Site: Arkansas Nuclear 
Issue date: 08/28/1973
From: Beratan L
US ATOMIC ENERGY COMMISSION (AEC)
To: Thornburg H
US ATOMIC ENERGY COMMISSION (AEC)
Shared Package
ML19326B348 List:
References
NUDOCS 8004150725
Download: ML19326B347 (1)


Text

1 y

1V

[

')

UMTED STATES

[)

j.'3 i

(.)

Y ATOMIC ENERGY COMMIS510N j

  • 7 w A 5HINGTON. O C.

20545 g.,

M AUG 2 8 r?

Tb py H. D. Tiornburphief, Field Support & Enforcement Branch, R0 l

THRU: 'G R

m't$t hief, Technical Assistance Branch, R0 DEFICIENCY IN FUEL HANDLING EQUIPMENT - ARKANSAS POWER & LIGHT DOCKET N0. 50-313 (F0-78)

I After assembly and testing of the fuel handling equipment supplied by Stearns-Rogers, it was discovered that the lower tube of the control rod grapple was loose. The tube mast is held in place by six 3/8 inch cap screws.

It was determined that the cap screws were not properly torqued and the nuts were not staked contrary to prescribed manufacturing procedures.

The bolt holes were found to be worn 1/16 of an inch. New holes were drilled, the bolts inserted, properly torqued and the nuts were staked.

This problem nas not been identified at any other facility using ry similar equipment. On this basis we consider this to be a breakdown

(

)

of the manufacturer's QC program and does not appear to have generic G'

implications.

hYh&E L. L. Beratan Senior Structural Engineer Technical Assistance Branch, R0

[')

.V t