eg UNITED STATES h
TOMIC ENERGY COMMISSION
'5b l WASHINGTON. D.C. 20545
,,,,,,,, /
u N 19 U74 E. J. Brunner, RO:I W. C. Seidle, RO:II C. E. Murphy, RO:II G. S. Spencer, RO:V FLOW ORIFICE DESIGN DEFICIENCY Enclosed for your information and possible action are copies of
'I CDR#247 and an evaluation memorandum prepared by TAB concerning the subject deficiency.
d We concur in TAB's recommendation that RO inspection attention be provided to assure orifice replacement at the affected facilities.
)
i ffh LLS' C
l' D 1arold D.(Thornburg, Chief Field Support & Enforcement Bran Directorate of Regulatory Operations CP
~a 800415071f 3
,gT5'N V QO'313)